2019
DOI: 10.1002/jcc.25865
|View full text |Cite
|
Sign up to set email alerts
|

Electrode polarization effects on interfacial kinetics of ionic liquid at graphite surface: An extended lagrangian‐based constant potential molecular dynamics simulation study

Abstract: Computational models including electrode polarization can be essential to study electrode/electrolyte interfacial phenomena more realistically. We present here a constant‐potential classical molecular dynamics simulation method based on the extended Lagrangian formulation where the fluctuating electrode atomic charges are treated as independent dynamical variables. The method is applied to a graphite/ionic liquid system for the validation and the interfacial kinetics study. While the correct adiabatic dynamics… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 12 publications
(15 citation statements)
references
References 64 publications
0
5
0
Order By: Relevance
“…Further, the voltage effect should also be considered, especially in modeling the SEI film formation process. Its function was implemented as a controlling variable 77 into the original RM algorithm to improve the predictability to design a high-performance electrolyte for next-generation NIBs.…”
Section: Summary and Future Perspectivementioning
confidence: 99%
“…Further, the voltage effect should also be considered, especially in modeling the SEI film formation process. Its function was implemented as a controlling variable 77 into the original RM algorithm to improve the predictability to design a high-performance electrolyte for next-generation NIBs.…”
Section: Summary and Future Perspectivementioning
confidence: 99%
“…This is consistent with the simulation of an electrochemical cell under open-circuit conditions. Note that we use here a hybrid method, where E is not constant along the direction perpendicular to the electrode, while it is kept constant to 0 in the parallel direction, an approach similar to previous studies. , The approach would also work straightforwardly if an extended Lagrangian scheme was used to compute the electrode atom charges …”
mentioning
confidence: 99%
“…11,13 The approach would also work straightforwardly if an extended Lagrangian scheme was used to compute the electrode atom charges. 20 In order to check the feasibility of the method, we have simulated a nanocapacitor made of a single graphite electrode and the 1-ethyl-3-methylimidazolium hexafluorophosphate ionic liquid for the electrolyte. This system was chosen because its electrochemical characteristics have already been studied using constant applied potential MD simulations.…”
mentioning
confidence: 99%
“…43,44 This additional attraction also makes a difference in interfacial kinetics—it causes the interface to relax much slower when the applied potential is suddenly removed. 45…”
Section: Constant Potential Methodsmentioning
confidence: 99%
“…43,44 This additional attraction also makes a difference in interfacial kinetics-it causes the interface to relax much slower when the applied potential is suddenly removed. 45 To compensate for the missed polarization effect, the image charge method (ICM) 46 can be used on top of FCM to include the additional attraction (Fig. 1b).…”
Section: Constant Potential Methods In Cmdmentioning
confidence: 99%