“…Other characteristics of the CVs were comparable with previous reports [3,8]; in particular, the capacitive currents were significantly lower than those observed at macro-electrodes of the same geometric area.…”
“…2b) in solutions containing (sub)micromolar concentrations of FA + . At variance with the CV case [3,8], DPV peak currents (faradaic currents) at the NEE are slightly lower than those at the Au-macro. This is related to the smaller time scale of the DPV experiments, this parameter being equal to the pulse time for such a technique (namely, 50 ms for DPV in the experimental conditions of Fig.…”
Section: Differential Pulse Voltammetry With Nees For Trace Analysesmentioning
confidence: 59%
“…Experiments showed that for f values between 10 −3 and 10 −2 detection limits at NEEs were 2-3 orders of magnitude lower than with conventional electrodes [3,8,10]. However, NEEs of rather large geometric area (typically 0.07 cm 2 ) were used in these experiments.…”
Section: Introductionmentioning
confidence: 91%
“…The nanoelectrode ensembles were prepared using the electroless plating procedure described previously [3] and following modifications [8].…”
Section: Preparation Of the Electrodesmentioning
confidence: 99%
“…The theory developed by Amatore et al [7] for electrodes with partially blocked surface has been applied successfully for measuring heterogeneous electron transfer rate constants at NEEs [3,8]. Cyclic voltammetric responses at regular microdisc electrode arrays were also simulated recently [9], showing that there is a minimum number of elements in the array above which the normalized current response become independent on the size of the array.…”
“…Other characteristics of the CVs were comparable with previous reports [3,8]; in particular, the capacitive currents were significantly lower than those observed at macro-electrodes of the same geometric area.…”
“…2b) in solutions containing (sub)micromolar concentrations of FA + . At variance with the CV case [3,8], DPV peak currents (faradaic currents) at the NEE are slightly lower than those at the Au-macro. This is related to the smaller time scale of the DPV experiments, this parameter being equal to the pulse time for such a technique (namely, 50 ms for DPV in the experimental conditions of Fig.…”
Section: Differential Pulse Voltammetry With Nees For Trace Analysesmentioning
confidence: 59%
“…Experiments showed that for f values between 10 −3 and 10 −2 detection limits at NEEs were 2-3 orders of magnitude lower than with conventional electrodes [3,8,10]. However, NEEs of rather large geometric area (typically 0.07 cm 2 ) were used in these experiments.…”
Section: Introductionmentioning
confidence: 91%
“…The nanoelectrode ensembles were prepared using the electroless plating procedure described previously [3] and following modifications [8].…”
Section: Preparation Of the Electrodesmentioning
confidence: 99%
“…The theory developed by Amatore et al [7] for electrodes with partially blocked surface has been applied successfully for measuring heterogeneous electron transfer rate constants at NEEs [3,8]. Cyclic voltammetric responses at regular microdisc electrode arrays were also simulated recently [9], showing that there is a minimum number of elements in the array above which the normalized current response become independent on the size of the array.…”
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.