2023
DOI: 10.3390/s23031084
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical System for Field Control of Hg2+ Concentration in Wastewater Samples

Abstract: The paper presents the validation of an electrochemical procedure for on-site Hg2+ ions determination in wastewater samples using a modified carbon screen-printed electrode (SPE) with a complexing polymeric film based on poly(2,2′-(ethane-1,2-diylbis((2-(azulen-2-ylamino)-2-oxoethyl)azanediyl))diacetic acid) (polyL). Using metal ions accumulation in an open circuit followed by anodic stripping voltammetry, the SPE-polyL electrode presents a linear range in the range of 20 µg/L to 150 µg/L, with a limit of dete… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 50 publications
(56 reference statements)
0
3
0
Order By: Relevance
“…A factor would be considered to have a significant effect if it exceeds the value of 1.4 times SR (limit of acceptance). 28 Based on that, as can be seen in Table 4, the robustness test showed a significant effect from pH, followed by a non-significant effect from temperature and Mg 2+ concentration.…”
Section: Resultsmentioning
confidence: 81%
See 1 more Smart Citation
“…A factor would be considered to have a significant effect if it exceeds the value of 1.4 times SR (limit of acceptance). 28 Based on that, as can be seen in Table 4, the robustness test showed a significant effect from pH, followed by a non-significant effect from temperature and Mg 2+ concentration.…”
Section: Resultsmentioning
confidence: 81%
“…2.5.5 Robustness. The robustness tests were conducted using the Youden and Steiner partial factorial model, 28,29 which involved deliberately changing three factors from their normal conditions. The selected factors for the experiment were pH, temperature, and Mg 2+ concentration in the hybridization buffer.…”
Section: Electrochemical Performance Of E-biosensormentioning
confidence: 99%
“…Finally, 2D Sbexf-SPCNFE was successfully applied to the determination of Cd­(II) and Pb­(II) traces in a certified estuary water sample. This paper presents the validation of an electrochemical procedure for on-site Hg 2+ ion determination in wastewater samples using a modified carbon screen-printed electrode (SPE) with a complexing polymeric film based on poly­[2,2′-(ethane-1,2-diylbis­((2-(azulen-2-ylamino)-2-oxoethyl)­azanediyl)]­diacetic acid) (polyL). Using metal ion accumulation in an open circuit followed by anodic stripping voltammetry, the SPE-polyL electrode presents a linear range of 20 to 150 _g/L, with a limit of detection (LOD) = 6 _g/L, limit of quantification (LOQ) = 20 _g/L, and an average measurement uncertainty of 26% of mercury ions.…”
Section: Methodsmentioning