2022
DOI: 10.1016/j.microc.2022.107633
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical sensor based on molecularly imprinted polymer coating on metal–organic frameworks for the selective and sensitive determination of carbendazim

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 20 publications
(11 citation statements)
references
References 28 publications
0
11
0
Order By: Relevance
“…In order to remove the template molecules, a Soxhlet system with methanol : chloroform mixture (9 : 1 v/v) was used for 48 h. Finally, the HKUST-1@MIP was dried at 40 °C for one hour under vacuum and stored in a desiccator for further use. 48 This sensor displayed a dynamic range of 0.01 to 50 μM with a LOD of 2 nM, and was shown to measure carbendazim within spiked tangerine, tomato, apple and cucumber juices, which was validated against HPLC and showed that the HKUST-1@MIP sensor has practicability and effectiveness in the validation of real samples. Fig.…”
Section: Electroanalytical Based Sensors For Carbendazimmentioning
confidence: 97%
See 2 more Smart Citations
“…In order to remove the template molecules, a Soxhlet system with methanol : chloroform mixture (9 : 1 v/v) was used for 48 h. Finally, the HKUST-1@MIP was dried at 40 °C for one hour under vacuum and stored in a desiccator for further use. 48 This sensor displayed a dynamic range of 0.01 to 50 μM with a LOD of 2 nM, and was shown to measure carbendazim within spiked tangerine, tomato, apple and cucumber juices, which was validated against HPLC and showed that the HKUST-1@MIP sensor has practicability and effectiveness in the validation of real samples. Fig.…”
Section: Electroanalytical Based Sensors For Carbendazimmentioning
confidence: 97%
“…41–44 To this end, a variety of MIP sensors have been reported for the sensitive levels of carbendazim. 45–49 Fig. 3A shows how a C-ZIF67@Ni/MIP has been made for the detection of carbendazim from 0.4 pM to 1 nM with a LOD of 0.135 pM.…”
Section: Electroanalytical Based Sensors For Carbendazimmentioning
confidence: 99%
See 1 more Smart Citation
“…In 2022, Beigmoradi et al designed a MIP-coated MOF-based electrochemical sensor for carbendazim. 55 In this work, HKUST-1 was used as the substrate material, methacrylic acid as the functional monomer and ethylene glycol dimethacrylate as the cross-linker in the presence of a carbendazim template. It is due to the large surface area of HKUST-1 that the sensor has excellent sensing properties.…”
Section: Mofs As a Recognition Platform Through An Electrochemical Se...mentioning
confidence: 99%
“…Conversely, electrochemical techniques have attracted much attention for measuring MAL and CBZ due to their advantages, such as low detection limits, excellent sensitivity, relative simplicity, reproducibility, portability, low cost, and short sample preparation time. 24,25 Computational chemistry is a subset of chemistry that uses mathematical sciences, statistics, and computer programs to investigate molecular structures, properties, and chemical reactions. 26 This science can help experimental chemistry.…”
Section: Introductionmentioning
confidence: 99%