2020
DOI: 10.1134/s1023193520060051
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical Sensing System Based on MnFe2O4/rGO for Simultaneous Determination of Trace Amount Pb2+ and Cd2+ in Spice Samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 41 publications
0
2
0
Order By: Relevance
“…Therefore, the anti-interference ability of the modified electrode is one of the most crucial parameters impacting the accuracy of monitoring [ 169 ]. The tolerance limit is taken as the concentration of the interference ion that causes a relative standard error of <5 % in the observed peak currents or detection limits [ 24 , 75 , 134 , 136 , 184 ]. Alternatively, the ratio (I I /I O ) of the currents in presence (I I ) and in absence (I o ) of interfering ion (s) is obtained, with a value of 1 indicating high anti-interference abilities of the modified electrode [ 154 ].…”
Section: Performance Of Iron Oxide Based Modified Electrodesmentioning
confidence: 99%
“…Therefore, the anti-interference ability of the modified electrode is one of the most crucial parameters impacting the accuracy of monitoring [ 169 ]. The tolerance limit is taken as the concentration of the interference ion that causes a relative standard error of <5 % in the observed peak currents or detection limits [ 24 , 75 , 134 , 136 , 184 ]. Alternatively, the ratio (I I /I O ) of the currents in presence (I I ) and in absence (I o ) of interfering ion (s) is obtained, with a value of 1 indicating high anti-interference abilities of the modified electrode [ 154 ].…”
Section: Performance Of Iron Oxide Based Modified Electrodesmentioning
confidence: 99%
“…However, most of the sensitive and selective methods based on anodic stripping voltammetry (ASV) [5] , inductive coupled plasma atomic emission spectrometry (ICP-AES) [6] , atomic absorption spectrometry (AAS) [7] and inductively coupled plasma-mass spectrometry (ICP-MS) [8] have the problems such as professional operator, complex sample pretreatment process and expensive equipment. To address the above issue, many new sensors such as surface enhancement of Raman scattering (SERS)-based sensor [15][16] , electrochemical-based sensor [17][18] , colorimetric-based sensor [19][20] , fluorescence-based sensor [6,21] has been reported to determine Cd 2+ . Varied shortcoming still exists in the new sensors despite their individual advantages.…”
Section: Introductionmentioning
confidence: 99%