Electrochemical Relaxation Techniques

Abstract: ITHIN the past 20 years a wide W variety of electroanalytical techniques have been newly developed and a number of previously conceived techniques have received r2newed attention as a result of electronic advances which facilitated their practical implementation. The purpose of the present review, rather than considering only the advances of the past tv.oyears, will be t o discuss the relative merits of a selection of these methods. No attempt has been made at completely surveying the extensive literature, and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
16
0
2

Year Published

1964
1964
1979
1979

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(18 citation statements)
references
References 46 publications
0
16
0
2
Order By: Relevance
“…In one way or another these nonfaradaic influences limit the scope of voltammetric methods in kinetic and mechanistic studies of electrode reactions as well as in analytical applications. Particularly profound are their effects in modern electrochemical relaxation methods such as cyclic voltammetry (16,20,25,42), a.c. polarography (55,57,64,70,71), and high-speed potentiostatic measurements (10,11,87,55). The contributions of iR drop and double-layer charging current in these latter techniques can be made minimal in measurements involving time scales (the period of the alternating potential in a.c. polarography and cyclic voltammetry, the measurement time in chrono-amperometry, etc.)…”
mentioning
confidence: 99%
“…In one way or another these nonfaradaic influences limit the scope of voltammetric methods in kinetic and mechanistic studies of electrode reactions as well as in analytical applications. Particularly profound are their effects in modern electrochemical relaxation methods such as cyclic voltammetry (16,20,25,42), a.c. polarography (55,57,64,70,71), and high-speed potentiostatic measurements (10,11,87,55). The contributions of iR drop and double-layer charging current in these latter techniques can be made minimal in measurements involving time scales (the period of the alternating potential in a.c. polarography and cyclic voltammetry, the measurement time in chrono-amperometry, etc.)…”
mentioning
confidence: 99%
“…There is, in addition, a whole segment of methods in which current, rather than potential, is controlled (chronopotentiometric or galvanostatic techniques). For a thorough treatment of these the reader is referred to several monographs (2,3,6) and the reviews on "relaxation methods" by Reinmuth (24), and "electroanalysis and coulometric methods" by Bard (25). In addition, amperometric methods, while usually carried out in stirred solution, embody the principles of voltammetry discussed in the previous sections.…”
Section: Chronoamperometry-inmentioning
confidence: 99%
“…Obwohl z. Zt. no& keine speziellen Polarographen kommerziell fur diesen Kreis jungst entwickelter Verfahren [6], [8], [61] erhaltlich sind, sei abschlieRend auf sie eingegangen, zumal man klar voraussehen kann, daR ihre Anwendung in naher Zukunft auaerordentliche Bedeutung gewinnen wird. Diese Verfahren stellen einen ganz entscheidenden methodischen Fortschritt dar, der nicht nur die Moglichkeiten der elektrochemischen Spurenanalyse betrachtlich erweitert, sondern vor allem auch einen ganz neuen Abschnitt fur die elektrochemische Kinetik eingeleitet hat.…”
Section: Second Order Techniques"unclassified
“…Hingegen hat der Kapazitatsstrom wegen des weitgehend linearen Charakters der Doppelschichtkapazitat nur einen sehr geringfugigen Oberwellengehalt. Registriert man daher nach Ausfilterung mit einem HochpaBfilter nur die hoheren Harmonischen, so ergibt sich eine weitere sehr wirkungsvolle Moglichkeit zur Ausschaltung des Kapazitatsstromes[6],[8],[61],[?3] -[??I. Da bei fundamentalen Studien zur Elektrodenkinetik Messungen bei verschiedenen Frequenzen in einem weiten Bereich moglich sein mussen, wird aber der apparative Aufwand sehr groB im Vergleich zu anderen Nichtlinearitatstechniken, wie der faradayschen Gleichrichtung; denn das HochpaRfilter muB eine enge aber in weitem Bereich variable Bandbreite haben.…”
unclassified