2002
DOI: 10.1016/s0013-4686(02)00439-5
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical noise analysis of cathodically polarised AISI 4140 steel. I. Characterisation of hydrogen evolution on vertical unstressed electrodes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
0

Year Published

2004
2004
2015
2015

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 22 publications
(17 citation statements)
references
References 26 publications
0
16
0
Order By: Relevance
“…Several studies performed on stainless steel under various conditions [17] [18] [19] [20] have indicated that it might be possible to measure electrochemical current and voltage noise fluctuations resulting from the periodic activation and propagation of cracks on SCC tests. In some investigations [21] [22] hydrogen embrittlement as a particular kind of SCC and the influence of evolved hydrogen bubbles on the measured EN received special attention.…”
Section: Introductionmentioning
confidence: 99%
“…Several studies performed on stainless steel under various conditions [17] [18] [19] [20] have indicated that it might be possible to measure electrochemical current and voltage noise fluctuations resulting from the periodic activation and propagation of cracks on SCC tests. In some investigations [21] [22] hydrogen embrittlement as a particular kind of SCC and the influence of evolved hydrogen bubbles on the measured EN received special attention.…”
Section: Introductionmentioning
confidence: 99%
“…Some authors 19 have used a similar approach on pre‐cracked coated CT specimens, and found certain oscillations in the measured current, presumably connected to the periodic propagation of the crack. In a few investigations 20, 21 hydrogen embrittlement as a particular kind of SCC and the influence of evolved hydrogen bubbles on the measured EN received special attention.…”
Section: Introductionmentioning
confidence: 99%
“…Poten tiostatic/Galvanostatic mode is usually applied in lab studies, such as SCC monitoring and gas evolution [3,[36][37][38]. In this case, we can only obtain ECN under potentiostatic control or EPN under galvano static control, but we cannot get both of them.…”
Section: Potentiostatic/galvanostatic Modementioning
confidence: 99%
“…EN is used in the corrosion engineering field in the beginning and now extends to many other fields like electrodepo sition [1,2], gas evolving electrode [3][4][5], and fuel cells operation [6], as shown in Fig. 1.…”
Section: Introduction Electrochemical Noise (En) Is the Generic Termmentioning
confidence: 99%