2012
DOI: 10.1016/j.talanta.2012.06.055
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical nanoporous alumina membrane-based label-free DNA biosensor for the detection of Legionella sp

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
44
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 50 publications
(46 citation statements)
references
References 36 publications
1
44
0
Order By: Relevance
“…Due to the surface chemistry of anodic alumina, the pore walls are being functionalized, and numerous sensors are being formed. The detection of glucose oxidase [113], thrombin [55], DNA [211,260,263], surface active agents [123], Ara h1 peanut protein [231], trypsin [222], and urea [281] is enabled. Moreover, application Özt€ urk et al [194] Fig .…”
Section: Applications Of Anodic Aluminum Oxidementioning
confidence: 99%
“…Due to the surface chemistry of anodic alumina, the pore walls are being functionalized, and numerous sensors are being formed. The detection of glucose oxidase [113], thrombin [55], DNA [211,260,263], surface active agents [123], Ara h1 peanut protein [231], trypsin [222], and urea [281] is enabled. Moreover, application Özt€ urk et al [194] Fig .…”
Section: Applications Of Anodic Aluminum Oxidementioning
confidence: 99%
“…All electrolyte buffer solutions were purge with nitrogen for 10 min to remove dissolved oxygen prior to the measurement. Configuration of the self assembled layer and immobilization was declared by cyclic voltammetry (CV) in a 0.1 M phosphate buffer saline (pH 7.0) containing 1.0 mM K 3 Fe(CN) 6 at a scan rate of 25 …”
Section: Electrochemical Detectionmentioning
confidence: 99%
“…Electrochemical responses were detected by differential pulse voltammetry under the constant MB at 20 µM in 20 mM Tris buffer saline as it has been suggested that the DPV can remove capacitive currents and known to increase detection limits compared to non-pulsed voltammetry by two fold differences [25] [26]. The plots of overall obtaining reduction peak current of MB are displayed in Figure 4.…”
Section: Electrochemical Responses Of the Complementary Scwl-dna Targmentioning
confidence: 99%
See 1 more Smart Citation
“…Moreover, at the nanoscale, as the diameter of the nanopore is comparable to the size of biomolecules, it is also possible to observe the effect of the volume exclusion in conductance change. Such a blocking effect can be further amplified by nanoparticle tags attached on target molecules [6,8,14,[19][20][21][22].…”
Section: Introductionmentioning
confidence: 99%