2009
DOI: 10.1016/j.corsci.2009.01.006
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical frequency modulation and inductively coupled plasma atomic emission spectroscopy methods for monitoring corrosion rates and inhibition of low alloy steel corrosion in HCl solutions and a test for validity of the Tafel extrapolation method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
37
0

Year Published

2009
2009
2017
2017

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 150 publications
(38 citation statements)
references
References 49 publications
1
37
0
Order By: Relevance
“…The Nyquist plots show depressed semi-circles, having one capacitive loop. The analysis of Nyquist plots reveals that the corrosion process is mainly charge transfer controlled [19]. The diameter of the capacitive loops increases with increasing concentrations of inhibitors suggesting that both FA and EA act as efficient corrosion inhibitors for MS.…”
Section: Electrochemical Impedance Spectroscopymentioning
confidence: 99%
See 1 more Smart Citation
“…The Nyquist plots show depressed semi-circles, having one capacitive loop. The analysis of Nyquist plots reveals that the corrosion process is mainly charge transfer controlled [19]. The diameter of the capacitive loops increases with increasing concentrations of inhibitors suggesting that both FA and EA act as efficient corrosion inhibitors for MS.…”
Section: Electrochemical Impedance Spectroscopymentioning
confidence: 99%
“…Nowadays, researchers are mainly focusing on the use of non-toxic and ''green'' corrosion inhibitors, e.g., plant extracts and drugs to obviate the harmful effect of chemicals on environment [8][9][10]. Because of their non-toxic characteristics [18] and negligible negative impacts on the aquatic environment [19], drugs (chemical medicines) seem to be the ideal candidates to replace traditional toxic corrosion inhibitors [9]. A number of studies are available describing the application of drugs as efficient corrosion inhibitors [9][10][11][12][13][14][15][16][17].…”
Section: Introductionmentioning
confidence: 99%
“…The EDAXs survey spectra were used to determine the elements present on the mild steel surface before and after exposure to the inhibitor solution [28][29][30]. The objective of this section was to confirm the results obtained from chemical and electrochemical measurements that a protective surface film of inhibitor is formed on the mild steel surface.…”
Section: Energy Dispersive Analysis Of X-rays (Edaxs)mentioning
confidence: 92%
“…To understand the nature of the surface film in the absence and presence of inhibitors and the extent of corrosion of mild steel, the SEM micrographs of the surface are examined [28][29][30]. The SEM images of different magnification (×20) of mild steel specimen immersed in an aqueous containing 60 ppm Cl -for one day in the absence and presence of inhibitor system are shown in Fig.…”
Section: Sem Analysis Of Mild Steel Surfacementioning
confidence: 99%
“…The most precise determination of the corrosion current density values is by the Tafel extrapolation when both the anodic and cathodic branches show linearity. However, it is also possible to make an accurate evaluation of the corrosion current densities if one of the branches of the polarization curves displays a sufficiently long linear tendency around the corrosion potential [24][25][26][27]. In fact, two rules of thumb should be applied when using Tafel extrapolation.…”
Section: Electrochemical Equipment and Measurementsmentioning
confidence: 99%