2007
DOI: 10.1016/j.talanta.2006.08.026
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical determination of dopamine and ascorbic acid at a novel gold nanoparticles distributed poly(4-aminothiophenol) modified electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
55
0
2

Year Published

2008
2008
2019
2019

Publication Types

Select...
6
3
1

Relationship

0
10

Authors

Journals

citations
Cited by 127 publications
(59 citation statements)
references
References 35 publications
2
55
0
2
Order By: Relevance
“…This sensitivity is reasonable given the fact that the sensitivities of the majority of polymer modified dopamine sensors are similar, if not, lower than this. For example, Gopalan et al [36] obtained a sensitivity of 0.22 A M −1 in the presence of ascorbic acid using a poly(4-aminothiophenol) modified electrode embedded with gold nanoparticles while Balamurugan and Chen [37] acquired a sensitivity of 1.0 A M −1 for dopamine using an poly(3,4-ethylenedioxythiophene-co-(5-amino-2-naphthalenesulfonic acid)) modified electrode.…”
Section: Sensitivity Of the Polypyrrole Sulfonatedˇ-cyclodextrin Filmmentioning
confidence: 99%
“…This sensitivity is reasonable given the fact that the sensitivities of the majority of polymer modified dopamine sensors are similar, if not, lower than this. For example, Gopalan et al [36] obtained a sensitivity of 0.22 A M −1 in the presence of ascorbic acid using a poly(4-aminothiophenol) modified electrode embedded with gold nanoparticles while Balamurugan and Chen [37] acquired a sensitivity of 1.0 A M −1 for dopamine using an poly(3,4-ethylenedioxythiophene-co-(5-amino-2-naphthalenesulfonic acid)) modified electrode.…”
Section: Sensitivity Of the Polypyrrole Sulfonatedˇ-cyclodextrin Filmmentioning
confidence: 99%
“…On the other hand, the diffraction characteristic peaks for PEDOT-Au nanocomposite appeared at 2y 38. [8,9,28]. The broadening of XRD peaks suggests the formation of nanocrystallites.…”
Section: Characterization Of Nanometallic Particles/polymer Compositementioning
confidence: 99%
“…Literature reveals that all these important characteristics cannot be inbuilt in a single material. Hence, there is always a demand for the development of composite materials, comprising two or more components, to achieve adequate sensitivity and stability for the biosensors [2][3][4].…”
Section: Introductionmentioning
confidence: 99%