2008
DOI: 10.1016/j.snb.2007.08.017
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical detection of trace amount of arsenic(III) at glassy carbon electrode modified with cobalt oxide nanoparticles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

5
104
0
3

Year Published

2008
2008
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 230 publications
(112 citation statements)
references
References 54 publications
5
104
0
3
Order By: Relevance
“…Studies using Co and cobalt oxides (CoO) decorated electrodes for biological and environmental sensing have been reported [28][29][30][31][32]. Electrodes decorated with CoO nanoparticles without CNTs for sensing properties have also been studied [33,34]. However, few studies using CNT-Co modified electrodes have been carried out [35][36][37][38][39], prepared mainly by chemical reduction processes rather than by electrodeposition.…”
Section: Introductionmentioning
confidence: 99%
“…Studies using Co and cobalt oxides (CoO) decorated electrodes for biological and environmental sensing have been reported [28][29][30][31][32]. Electrodes decorated with CoO nanoparticles without CNTs for sensing properties have also been studied [33,34]. However, few studies using CNT-Co modified electrodes have been carried out [35][36][37][38][39], prepared mainly by chemical reduction processes rather than by electrodeposition.…”
Section: Introductionmentioning
confidence: 99%
“…20 Among other methods are silver electrode, 21 Platinum (Pt) nanoparticle modified GCE, 22 Pt nanotube, 23 Pt modified BDD electrode, 24 Iridium-implanted BDD electrode, 25 arsenite oxidase biosensor, 26 screen printed ring disk carbon electrode, 27 and cobalt oxide nanoparticle modified GCE. 28 Most studies using these modified electrodes adopted anodic stripping voltammetry (ASV) for more effective and sensitive detection of arsenic. Although these modified electrodes show the successful determination of As(III) with a low limit of detection (LOD) via anodic stripping voltammetry, their sensitivities remain relatively low level and they suffers from the problem of copper interference.…”
mentioning
confidence: 99%
“…Analysis of As (III) on the Au spikes was carried out via Square Wave Anodic Stripping Voltammetry (SWASV) in 0.5 M HNO 3 . SWASV responses of the three gold spike electrodes with different concentrations of As (III) are shown in Figures 2a-2c.…”
Section: Resultsmentioning
confidence: 99%
“…All the solutions were prepared with Milli-Q (18 M cm −1 ) deionized water. As (III) stock solution was prepared by dissolving As 2 O 3 in concentrated NaOH, and the pH was adjusted to 3.0 with concentrated HNO 3 and then diluted with Milli-Q water. Solutions of other concentrations were prepared from this stock solution.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation