2014
DOI: 10.1016/j.jelechem.2014.01.013
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical detection of butylated hydroxyanisole based on glassy carbon electrode modified by iridium oxide nanoparticles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(9 citation statements)
references
References 43 publications
0
9
0
Order By: Relevance
“…In 2012, the EFSA's panel of food additives concluded that the exposure to BHA as a food additive did not exceed the ADI of 1 mg/kg of body weight, even for the highest consuming population, but, this ADI was exceeded when the combined exposure as food additive and food contact material was taken into consideration. The target of BHA is controlling rancidification of animal fat in foodstuffs, given its low effectiveness on vegetable fat (Branen et al, 2001;EFSA, 2011;Roushani & Sarabaegi, 2014;Wang et al, 2015).…”
Section: Butylates (E319 -E321)mentioning
confidence: 99%
“…In 2012, the EFSA's panel of food additives concluded that the exposure to BHA as a food additive did not exceed the ADI of 1 mg/kg of body weight, even for the highest consuming population, but, this ADI was exceeded when the combined exposure as food additive and food contact material was taken into consideration. The target of BHA is controlling rancidification of animal fat in foodstuffs, given its low effectiveness on vegetable fat (Branen et al, 2001;EFSA, 2011;Roushani & Sarabaegi, 2014;Wang et al, 2015).…”
Section: Butylates (E319 -E321)mentioning
confidence: 99%
“…The results displayed a linear detection range from 0.1 to 1.0 μM with a detection limit of 0.0949 μM. Roushani and co-workers demonstrated an iridium oxide nanoparticle-modified GCE for BHA determination [16]. The results indicated the proposed method had a linear range from 1~280 μM with a detection limit of 0.6 μM.…”
Section: Introductionmentioning
confidence: 94%
“…Electrochemical methods have been applied for the determination of BHA due to their simplicity, sensitivity, stability, rapid response, and low cost [14][15][16][17][18][19][20][21][22][23][24][25][26]. For instance, the electrochemical oxidation of BHA at a glassy carbon electrode (GCE) that was modified with AuNPs-PVP-graphene was investigated [14].…”
Section: Introductionmentioning
confidence: 99%
“…31 Because of the high electron transfer rate constant of Ir(IV)/Ir(III) redox couple, IrO x were used as an electron transfer mediator and successfully applied in electrocatalysis. [52][53][54][55] The present research reports an amperometric sensor for nitrite and AA detection, based on modified with iridium oxide GC electrode. As an electrode material, GC is distinguished by its chemical inertness, low background currents, wide potential window and low price.…”
Section: Introductionmentioning
confidence: 99%