2016
DOI: 10.1016/j.talanta.2016.03.003
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical co-detection of As(III), Hg(II) and Pb(II) on a bismuth modified exfoliated graphite electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
30
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 87 publications
(32 citation statements)
references
References 27 publications
2
30
0
Order By: Relevance
“…The applicability of electrodeposited Bi nanoparticles on an exfoliated graphite (EG) electrode was investigated for the co‐detection of As 3+ , Hg 2+ , and Pb 2+ , with limits of detection (LODs) of 0.83 μg L −1 for As 3+ and 0.46 μg L −1 for coexisting Pb 2+ and Hg 2+ . Real water samples from South Africa were examined after passing through a 0.2 μm filter, showing results comparable with those obtained by ICP‐OES technique …”
Section: Electrode Materials For Heavy Metal Sensingsupporting
confidence: 54%
See 1 more Smart Citation
“…The applicability of electrodeposited Bi nanoparticles on an exfoliated graphite (EG) electrode was investigated for the co‐detection of As 3+ , Hg 2+ , and Pb 2+ , with limits of detection (LODs) of 0.83 μg L −1 for As 3+ and 0.46 μg L −1 for coexisting Pb 2+ and Hg 2+ . Real water samples from South Africa were examined after passing through a 0.2 μm filter, showing results comparable with those obtained by ICP‐OES technique …”
Section: Electrode Materials For Heavy Metal Sensingsupporting
confidence: 54%
“…( Table ). Preparation of the final electrode requires the prerequisite process of functional material synthesis and a secondary casting process . The functional materials usually consist of conductive frameworks with functional component containing rich metal attachment sites and/or binding agents, including carbon, bismuth, MOF, and a fixed mass of graphite powder or liquid paraffin.…”
Section: Design Of Electrode Integrationmentioning
confidence: 99%
“…The linear plot of change in current (Δi) against Hg concentration (c) shows that the regression equation from the liner a plot was y(Δi)=0.0826x (c)+0.06186, with the correlation coefficient of 0.9968. The limit of detection (LOD) and limit of quantifications (LOQ) were calculated using 3 σ/m and 10 σ/m respectively, where the standard deviation (σ) was obtained from blank and m is the slope of the calibration curve (n=6). The LOD was found to be 0.1 μg L −1 whereas the LOQ was calculated as 0.515 μg L −1 .…”
Section: Resultsmentioning
confidence: 99%
“…(5) The analysis can be simplified by: the replacement of precious metal electrodes by inexpensive materials [44,47,33,60,[99][100][101][102][103][104]; analysis without removing oxygen from solution [38,55,75,91]; minimizing the sample preparation stage by eliminating the reduction of As(V) to As(III), and speciation of As in the field. Automation of procedures is helpful and there has been some research aimed at creating microfluidic total analysis systems which would be ideal for this purpose [4].…”
Section: As(iii) Determination By Anodic Stripping Voltammetry (Asv)mentioning
confidence: 99%