2015
DOI: 10.1016/j.jelechem.2015.02.023
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical and theoretical quantum approaches on the inhibition of C1018 carbon steel corrosion in acidic medium containing chloride using some newly synthesized phenolic Schiff bases compounds

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
52
0
1

Year Published

2016
2016
2019
2019

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 111 publications
(58 citation statements)
references
References 68 publications
4
52
0
1
Order By: Relevance
“…The thickness of this protective layer increases with the increase in inhibitor concentration, since more inhibitor will electrostatically adsorb on the electrode surface. This trend is in accordance with Helmholtz model, given by the following equation [10,18]:…”
Section: Impedance Spectroscopysupporting
confidence: 89%
See 2 more Smart Citations
“…The thickness of this protective layer increases with the increase in inhibitor concentration, since more inhibitor will electrostatically adsorb on the electrode surface. This trend is in accordance with Helmholtz model, given by the following equation [10,18]:…”
Section: Impedance Spectroscopysupporting
confidence: 89%
“…Langmuir's isotherm assumes that the adsorption of organic molecule on the adsorbent is monolayer and the adsorbed molecules occupy only one site and there are no interactions with other adsorbed species. The standard free energy of adsorption of inhibitor (∆G ads ) on steel surface can be evaluated with the following equation: (6) The value 55.5 in the above equation is the concentration of water in solution in mol.l -1 [10]. The negative values of ∆G ads suggest that the adsorption of DHBP on the steel surface is spontaneous.…”
Section: Adsorption Isothermmentioning
confidence: 99%
See 1 more Smart Citation
“…The addition of PLS at 1 vol.% shifted the cathodic current density to the passive direction and the corrosion potential (E corr ) to a more negative value. This is likely due to the adsorption of organic molecules on the cathodic active sites of steel surface (54,55). By increasing the PLS concentration to 2 vol.%, the cathodic and anodic current densities further decreased, with more pronounced shift seen on the cathodic side.…”
Section: Pdp Resultsmentioning
confidence: 98%
“…The choice of the inhibitor is based on two considerations, fi rstly, economic consideration and, secondly, high inhibition effi ciency. Both features obviously can be combined within the same molecule such as Schiff bases [12][13][14][15]. In the past few years, the corrosion inhibition of various metals such as aluminum, and of steel in acid solutions by Schiff bases with environmental considerations has attracted more attention [16,17].…”
Section: Introductionmentioning
confidence: 99%