2021
DOI: 10.1039/d0ay02328k
|View full text |Cite
|
Sign up to set email alerts
|

Electrocatalytic performance of tyrosinase detection in Penaeus vannamei based on a [(PSS/PPy)(P2Mo18/PPy)5] multilayer composite film modified electrode

Abstract: Polyoxometalates (POMs) are widely used in the preparation of sensors that detect the content of substances because of their excellent electron transfer capabilities. In this paper, the [(PSS/PPy)(P2Mo18/PPy)5] multilayer composite...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 60 publications
0
6
0
Order By: Relevance
“…According to the equation of LOD (limit of detection) = 3.3 × SD of intercept/slop ( Wang et al., 2017 ), where SD is the standard deviation of intercept, an outstanding LOD of 1.9 fM was extracted ( Figures S13 A and S13B). A comparison of the sensing performance of tyrosinase activity between our bio-FETs and documented methods ( Ciui et al., 2018 ; Ding et al., 2021 ; Li et al., 2012 , 2018 ; Liu et al., 2017 ; Wang et al., 2019 ; Yan et al., 2019 ; Yarman, 2018 ; Zhou et al., 2016 ) is shown in Table S2 . Compared to previously reported methods for tyrosinase sensing, our bio-FETs are more advantageous in LOD with an acceptable linear range, which could be used as an accurate screening approach to monitor the tyrosinase level.…”
Section: Resultsmentioning
confidence: 99%
“…According to the equation of LOD (limit of detection) = 3.3 × SD of intercept/slop ( Wang et al., 2017 ), where SD is the standard deviation of intercept, an outstanding LOD of 1.9 fM was extracted ( Figures S13 A and S13B). A comparison of the sensing performance of tyrosinase activity between our bio-FETs and documented methods ( Ciui et al., 2018 ; Ding et al., 2021 ; Li et al., 2012 , 2018 ; Liu et al., 2017 ; Wang et al., 2019 ; Yan et al., 2019 ; Yarman, 2018 ; Zhou et al., 2016 ) is shown in Table S2 . Compared to previously reported methods for tyrosinase sensing, our bio-FETs are more advantageous in LOD with an acceptable linear range, which could be used as an accurate screening approach to monitor the tyrosinase level.…”
Section: Resultsmentioning
confidence: 99%
“…In the food industry, POM-based ECSs have been studied to detect toxic substances, [39][40][41]56,57,69 food additives, 54,80,81 nutrient substances, 37,53 pesticide residues, 36,38 etc., conducive to ensure the safety and quality of food.…”
Section: Pom-based Ecss For Food Safetymentioning
confidence: 99%
“…3d). 36 By electrodeposition, a CS-rGO/P2Mo17Cu/PLL modied electrode was constructed, featuring high stability, high reproducibility and fast response time. Such a POM-based ECS was successfully applied to the qualitative and quantitative detection of eugenol residues in the kidney, liver and meat tissues of perch with high recoveries (85.43-93.60%).…”
Section: Pom-based Ecss For Food Safetymentioning
confidence: 99%
See 1 more Smart Citation
“…Tyrosinase (TYR), as a multifunctional copper-containing enzyme, is widely distributed in plants, animals, and microorganisms. Since TYR catalyzes the reaction of hydroxylation of monophenols to diphenols, TYR has been found as the key enzyme within the biosynthetic pathway of endogenous melanin. ,, In addition, the TYR activity is not only thought to be associated with melanoma cancer and skin diseases but is also the factor that influences the nutritional value of food. , Thus, monitoring the activity of TYR precisely possesses great significance from clinical diagnosis to the food industry. , In the past few years, a variety of methods have been reported for the detection of TYR, such as colorimetric, spectrophotometric, and fluorescence-based methods. ,,, However, these approaches generally require fluorogenic- or chromogenic-labeled substrates, which are expensive, complicated, and time-consuming . Therefore, it is desirable to develop a simple, label-free, and high-performance sensor platform for the detection of TYR.…”
mentioning