2016
DOI: 10.1134/s1023193516060112
|View full text |Cite|
|
Sign up to set email alerts
|

Electrocatalytic oxidation of hydrazine on poly(4-aminobenzene sulfonic acid)-modified glassy carbon electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 30 publications
0
7
0
Order By: Relevance
“…Additionally, the positive shift was observed in the anodic peak potential of TAM. The slope is between 0.50-0.75 indicates that the current is diffusion controlled and that it is 0.75-1.00 indicates that the current is adsorption controlled (Sadikoglu et al, 2016), (Moghaddam et al, 2017). The logarithm of peak current (log I) against the logarithm of scan rate (log v) was shown in (Fig.…”
Section: Figure-2 the Oxidation Peak Current Values Obtained From Dpv Voltammograms Of 100µmmentioning
confidence: 99%
“…Additionally, the positive shift was observed in the anodic peak potential of TAM. The slope is between 0.50-0.75 indicates that the current is diffusion controlled and that it is 0.75-1.00 indicates that the current is adsorption controlled (Sadikoglu et al, 2016), (Moghaddam et al, 2017). The logarithm of peak current (log I) against the logarithm of scan rate (log v) was shown in (Fig.…”
Section: Figure-2 the Oxidation Peak Current Values Obtained From Dpv Voltammograms Of 100µmmentioning
confidence: 99%
“…The logarithm of peak current (log I) against the logarithm of scan rate (log v) is shown in Figure 4. The plot of logarithm of peak current (log I) versus logarithm of scan rate (log v) has a slope of 0.6647 (theoretical value of 0.50-0.75) indicate that the peak is diffusion controlled [12,17,18]. The peak current values of the oxidation peak obtained from the DPV voltammograms of the solutions of 510 -5 M NAP prepared with different support electrolytes in the range from pH 2.0 to 10.0 are showed in Figure 5.…”
Section: The Nature Of the Oxidation Peak Of Naproxenmentioning
confidence: 99%
“…The correlation coefficient is very close to 1.0. Consequently, it is understood that the electrochemical-oxidation is diffusion controlled [12,17,18]. The logarithm of peak current (log I) against the logarithm of scan rate (log v) is shown in Figure 4.…”
Section: The Nature Of the Oxidation Peak Of Naproxenmentioning
confidence: 99%
See 1 more Smart Citation
“…Also, the thermodynamic reversible potential of the direct hydrazine fuel cell (DHFC) is quite high, being about 1.56 V . Furthermore, previous studies have revealed that no catalyst poisoning occurs during hydrazine electroxidation . The use of an alkaline solution in a fuel cell has numerous advantages, including increased efficiency, higher efficiency of both anodic and cathodic processes, availability of a much broader range of possible electrode materials with almost no sensitivity to the surface structure, and insignificant poisoning effects .…”
Section: Introductionmentioning
confidence: 99%