2017
DOI: 10.1016/j.ijhydene.2016.04.190
|View full text |Cite
|
Sign up to set email alerts
|

Electrocatalytic hydrogen production on a modified pencil graphite electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 22 publications
(15 citation statements)
references
References 38 publications
0
14
0
1
Order By: Relevance
“…3d) for the as dealloyed MG ribbon toward HER in acidic medium is evaluated to be 67 mV dec À1 , and it indicates that the HER reaction proceeds via Volmer-Heyrovsky mechanism (Volmer step: H + + e À / H ads ; Tafel slope: 120 mV dec À1 and Heyrovsky step: H + + H ads + e À / H 2(g) ; Tafel slope: 40 mV dec À1 ) with desorption as the rate-limiting step. 36,44 The Tafel slope for Pt catalyst is measured to be 24.5 mV dec À1 . Tafel slope for the current MG and reported electrocatalysts toward HER in the acid medium from other similar reports are given in Table S1.…”
Section: Resultsmentioning
confidence: 99%
“…3d) for the as dealloyed MG ribbon toward HER in acidic medium is evaluated to be 67 mV dec À1 , and it indicates that the HER reaction proceeds via Volmer-Heyrovsky mechanism (Volmer step: H + + e À / H ads ; Tafel slope: 120 mV dec À1 and Heyrovsky step: H + + H ads + e À / H 2(g) ; Tafel slope: 40 mV dec À1 ) with desorption as the rate-limiting step. 36,44 The Tafel slope for Pt catalyst is measured to be 24.5 mV dec À1 . Tafel slope for the current MG and reported electrocatalysts toward HER in the acid medium from other similar reports are given in Table S1.…”
Section: Resultsmentioning
confidence: 99%
“…İstenilen voltaj ve akım güç kaynağı ile sağlanarak belirlenen süreler sonunda alınan numunelerde gerekli analizler yapılmıştır. Her çalışma öncesinde elektrotlar üzerinde biriken kir ve pas kalıntılarını gidermek amacıyla önceden hazırlanan temizleme çözeltisi içerisinde (0,25 M H2SO4) 5 dakika bekletilmiştir [12]. Temizleme sonrası elektrotlar 100°C etüvde kurutulmuş, desikatörde sabit tartıma hazır hale getirilerek bir sonraki deney düzeneği için hazırlanmıştır.…”
Section: şEkil 1 Elektrokimyasal Deney Düzeneğiunclassified
“…Furthermore, these electrodes are described by sensitivity, and are considered a viable, renewable and economical alternative [ 14 ]. Their high activity, stability and cost-efficiency has boosted the interest of their use for other important electrochemical processes, such as hydrogen evolution reaction [ 17 ].…”
Section: Introductionmentioning
confidence: 99%