2020
DOI: 10.1007/s10008-020-04697-w
|View full text |Cite
|
Sign up to set email alerts
|

Electroanalysis based on stand-alone matrices and electrode-modifying films with silica sol-gel frameworks: a review

Abstract: Silica sol-gel matrices and its organically modified analogues that contain aqueous electrolytes, ionic liquids, or other ionic conductors constitute stand-alone solid-state electrochemical cells when hosting electrodes or serve as modifying films on working electrodes in conventional cells. These materials facilitate a wide variety of analytical applications and are employed in various designs of power sources. In this review, analytical applications are the focus. Solid-state cells that serve as gas sensors,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
14
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(14 citation statements)
references
References 98 publications
0
14
0
Order By: Relevance
“…Additionally, no formation of the blue colouring (Prussian Blue formation) was observed on the steel surface, confirming definitely that the obtained coating provides a compact and tight protective barrier. Moreover, the VTMS/EtOH/AcOH layer formed on the X20Cr13 steel blocked the transport of electrons to ferrocyanide ions, has manifested itself by the attenuation of the redox currents ( Figure 9 B) [ 49 , 50 ].…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…Additionally, no formation of the blue colouring (Prussian Blue formation) was observed on the steel surface, confirming definitely that the obtained coating provides a compact and tight protective barrier. Moreover, the VTMS/EtOH/AcOH layer formed on the X20Cr13 steel blocked the transport of electrons to ferrocyanide ions, has manifested itself by the attenuation of the redox currents ( Figure 9 B) [ 49 , 50 ].…”
Section: Resultsmentioning
confidence: 99%
“…The following electrolytes were selected for testing: acetic acid (AcOH) by Chempur (the method of depositing the coating based on VTMS and acetic acid was developed in previous studies [ 36 ]); lithium perchlorate (LiClO 4 ) by Fluka Chemika, as a strongly oxidizing anion of inhibiting properties [ 37 , 38 , 39 , 40 , 41 , 42 ]; sulphuric acid (VI) (H 2 SO 4 ) by Chempur; an acid medium, with a passive film forming on the metal surface, containing sparingly soluble thermodynamically stable oxidation products [ 43 , 44 , 45 , 46 ]; ammonia (NH 3 )- P.P.H. by Polskie Odczynniki Chemiczne; a basic medium, for controlling the hydrolysis and condensation rates [ 47 , 48 , 49 , 50 , 51 , 52 ]. …”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations