2018
DOI: 10.1002/9781119483687
|View full text |Cite
|
Sign up to set email alerts
|

Electrical Systems for Nuclear Power Plants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(7 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…Normal power system, backup/standby power system and emergency power system are three major components of onsite power system (Mazzoni, 2018). Figure 8 (a-c) schematically presents the typical bus configurations of normal, backup and emergency power systems.…”
Section: Electrical Systems In Nppmentioning
confidence: 99%
See 1 more Smart Citation
“…Normal power system, backup/standby power system and emergency power system are three major components of onsite power system (Mazzoni, 2018). Figure 8 (a-c) schematically presents the typical bus configurations of normal, backup and emergency power systems.…”
Section: Electrical Systems In Nppmentioning
confidence: 99%
“…The transition time is controlled within 5 ms due to which the system is called uninterrupted power supply system. It is to note that the whole UPS devices and emergency power system are class 1E devices, which means the devices and subsystems are designed and manufactured with highest standards and skills (Mazzoni, 2018).…”
Section: Electrical Systems In Nppmentioning
confidence: 99%
“…Thus, steady and methodical coordination among nuclear plant, grid, auxiliary power subsystems, and protection systems is essential to implement operating strategies and emergency measures [11,37]. The alternating/direct current power supplies and distribution systems, instrumentation and control systems, and containment electrical penetration assemblies are class 1E electrical systems [38]. These systems are interfaced with the nuclear plant and with other systems.…”
Section: Coordinationmentioning
confidence: 99%
“…O sistema de Transferência Automática de Barras (TAB) é altamente recomendado para manter a segurança de uma planta nuclear, bem como a continuidade nos processos [6,7]. Sem esse sistema, fontes alternadas de uma planta não garantem, por si só, o fornecimento seguro de energia.…”
unclassified
“…O termo TAB pode ser encontrado na literatura de diversas formas. Para as indústrias nucleares, a TAB é comumente encontrada como: Automatic Transfer [8], Bus Transfer [8,9], Automatic Bus Transfer [5,7]. Já com um aspecto de aplicação geral é encontrado como Motor Bus Transfer [10,11,12].…”
unclassified