2016 China International Conference on Electricity Distribution (CICED) 2016
DOI: 10.1109/ciced.2016.7576136
|View full text |Cite
|
Sign up to set email alerts
|

Electrical model and control method of heat pump water heaters for promoting renewable integration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2017
2017
2019
2019

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 7 publications
0
4
0
Order By: Relevance
“…The uninterruptible load, flexible load, non-deferrable load, and thermostatically controlled load are adjusted following the operational constraints in [42][43][44], respectively. The relationship between the original load profile and the adjusted load profile is therefore concluded by the linear function f ðÁÞ in 29, which is not detailed in this paper.…”
Section: Income and Constraints Of Aggregatormentioning
confidence: 99%
“…The uninterruptible load, flexible load, non-deferrable load, and thermostatically controlled load are adjusted following the operational constraints in [42][43][44], respectively. The relationship between the original load profile and the adjusted load profile is therefore concluded by the linear function f ðÁÞ in 29, which is not detailed in this paper.…”
Section: Income and Constraints Of Aggregatormentioning
confidence: 99%
“…To simplify the expression, we assume n = 1 for WH and n = 2 for AC. WHs are controlled by the required water temperature and hot water volume, which are included in the heat balance equation [24], as described below:…”
Section: Consumers' Participation In Dr Programmesmentioning
confidence: 99%
“…Equality constraint (27) represents power balance in the system, whereby, power from renewable energy sources and grid are used to meet the demand from hot water devices together with the domestic load during every sampling interval, j. Constraints (28) and (29) show the state variables, that is, temperature of water from HPWH and instantaneous shower respectively, must be between set minimum and maximum acceptable temperature in every sampling interval, j. Constraints (30)- (32) show how the control variables are bound.…”
Section: Mpc Optimization Problemmentioning
confidence: 99%
“…HPWHs are not only ideal in enhancing EE for domestic hot water systems [24], but have also been proven to be economically feasible [27]. Further, it is possible to shift the load using HPWHs increasing the prospect of integrating it with renewable energy sources [28]. Various control algorithms aiming to reduce energy consumption and its associated cost have been developed.…”
Section: Introductionmentioning
confidence: 99%