1960
DOI: 10.1038/jid.1960.52
|View full text |Cite
|
Sign up to set email alerts
|

Electrical Characteristics of the Skin

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
24
0
2

Year Published

1978
1978
2020
2020

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 107 publications
(27 citation statements)
references
References 5 publications
1
24
0
2
Order By: Relevance
“…Owing to the high electrical capacity of the lipophilic matrix in which corneocytes are embedded, the stratum corneum is conferred dielectric properties, resulting in the skin impedance: the force opposing the passage of electrical charge through the skin . Electrolytes present in the ISF of the viable epidermis, on the other hand, account for an electric potential, connected to the activity of electrically driven tissues, such the heart and muscles.…”
Section: Mns For Dermal Biopotential Measurementsmentioning
confidence: 99%
“…Owing to the high electrical capacity of the lipophilic matrix in which corneocytes are embedded, the stratum corneum is conferred dielectric properties, resulting in the skin impedance: the force opposing the passage of electrical charge through the skin . Electrolytes present in the ISF of the viable epidermis, on the other hand, account for an electric potential, connected to the activity of electrically driven tissues, such the heart and muscles.…”
Section: Mns For Dermal Biopotential Measurementsmentioning
confidence: 99%
“…Pulsed current: The persistent use of direct current (DC), proportional to time, can reduce the iontophoretic flux because of its polarization effect on the skin [66]. This can be overcome by the use of pulsed DC which is a direct current delivered in a periodic manner [5].…”
Section: Experimental Conditionsmentioning
confidence: 99%
“…Dieses Verfahren ist zulässig, da von verschiedenen Autoren gezeigt wurde [5,9,12,20,22,30], daß im Bereich von 0,03 cm* < A < 60 cm* und 0 Hz < f < 10 KHz annähernd gilt: \rr l * izcl ~ - (17) Hieraus läßt sich die spezifische Übergangsimpedanz |Z*c| definieren: |Z* c |-lZc|-A. (18) Für die Auswahl der geeigneten Daten aus der Literatur galten die folgenden Kriterien: Neben der Angabe der Elektroden-Haut-Kontaktfläche war die Angabe der Meßfrequenz erforderlich und der Hinweis, ob der Meßwert sich auf eine oder zwei in Serie liegende Hautstellen bezog.…”
Section: Spezifische üBergangsimpedanzunclassified
“…Für beliebige Kontaktflächen A läßt sich die maximal zu erwartende Ubergangsimpedanz abschätzen aus l/ 9 l Zümax/MQ (20) \ l + (0,113-f/Hz) 2 A/cm 2 . [17].…”
Section: Richtwerte Der üBergangsimpedanzunclassified