Electrical aging phenomena of medium voltage EPR cable energized by ac voltage with switching impulses superimposed

Abstract: Electrical aging of polymer insulated power cables has been an important subject of investigation in the last several decades. Cable insulation is placed under heavy electrical stress due to overvoltages occurring during switching operations taking place in the power system. Transients overriding the normal ac operation voltage are some of the most hazardous conditions for cable insulation life. Although a good understanding of aging mechanisms under single stress has been achieved, more research work is neede… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
4
0

Year Published

2013
2013
2016
2016

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 12 publications
(10 reference statements)
1
4
0
Order By: Relevance
“…Then the inception voltages start to increase. The similar trend was observed for PD measurements of EPR cable samples aged by switching impulses [18] and by rated ac voltage with switching impulses superimposed [5]. The fluctuation of PD inception voltages appears again at the aging time between 650 and 800 hrs.…”
Section: A Measurement Of Pd Parameterssupporting
confidence: 78%
See 2 more Smart Citations
“…Then the inception voltages start to increase. The similar trend was observed for PD measurements of EPR cable samples aged by switching impulses [18] and by rated ac voltage with switching impulses superimposed [5]. The fluctuation of PD inception voltages appears again at the aging time between 650 and 800 hrs.…”
Section: A Measurement Of Pd Parameterssupporting
confidence: 78%
“…In the past, the aging study of EPR cables under many different conditions has been carried out [5,16]. Tab.…”
Section: Analysis Of Measurement Datamentioning
confidence: 99%
See 1 more Smart Citation
“…Moreover, past studies [8] revealed that perfectly manufactured EPR material would not have significant aging under the ac electrical field stress that was less than 20 kV/mm. Under some extreme conditions, such as lightning surges and switching transient conditions in power systems, the local electric field stress could be over ten times the operational field stress [15][16][17]. The majority of the commercially available EPR cables have a maximum working temperature of 105°C.…”
Section: Epr Insulation Under Electrical and Thermal Stressmentioning
confidence: 99%
“…Among all of these stresses, the switching surges are treated as one of the most hazardous sources. Yet the detailed information regarding the aging mechanism caused by switching impulses is not fully understood, especially those regarding the long term behaviors of the polymeric cables [15][16][17].…”
Section: B Xlpe and Epr Cable Under Electrical Stressmentioning
confidence: 99%