Electric Water Heater Energy Consumption Determination Using Outlet Temperature and Volumetric Estimation

Abstract: This paper presents the use of outlet temperature and water meter data as inputs to a physical model of a domestic electric water heater (EWH) for estimating the energy consumption for various control settings. Four sets of actual household data, consisting of at least 7 consecutive days each, is used to determine the accuracy of the energy consumption estimates in comparison to measured energy consumption. Both the outlet temperature and water meter data inputs used were able to estimate the total energy inpu… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2018
2018
2018
2018

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 15 publications
(24 reference statements)
0
1
0
Order By: Relevance
“…Thermal mass (or thermal dispersion) flow measurement was used by Huijsing et al (1988) to measure low flow rate liquid flows (below 0.6 L min −1 ) in small diameter pipes (the measuring tube has an inner diameter of 13 mm). Thermal event detection and volumetric estimation were incorporated in an EWH energy usage model by Nel et al (2015) using a non-invasive temperature sensor installed on the outlet pipe. The data sample rate used was 1 min and the described system was more effective for longer duration flow events (7 to 10 min) and the minimum duration of a detectable usage event was 3 min.…”
Section: Related Workmentioning
confidence: 99%
“…Thermal mass (or thermal dispersion) flow measurement was used by Huijsing et al (1988) to measure low flow rate liquid flows (below 0.6 L min −1 ) in small diameter pipes (the measuring tube has an inner diameter of 13 mm). Thermal event detection and volumetric estimation were incorporated in an EWH energy usage model by Nel et al (2015) using a non-invasive temperature sensor installed on the outlet pipe. The data sample rate used was 1 min and the described system was more effective for longer duration flow events (7 to 10 min) and the minimum duration of a detectable usage event was 3 min.…”
Section: Related Workmentioning
confidence: 99%