2019
DOI: 10.1016/j.enconman.2019.06.079
|View full text |Cite
|
Sign up to set email alerts
|

Electric efficiency indicators and carbon dioxide emission factors for power generation by fossil and renewable energy sources on hourly basis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
29
0
2

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 67 publications
(41 citation statements)
references
References 16 publications
1
29
0
2
Order By: Relevance
“…Following a complete replicable methodology described in Reference 22 it has been possible to evaluate different power grid efficiency indicators on hourly basis considering the contribution of the energy sources in various manners.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Following a complete replicable methodology described in Reference 22 it has been possible to evaluate different power grid efficiency indicators on hourly basis considering the contribution of the energy sources in various manners.…”
Section: Methodsmentioning
confidence: 99%
“…Þ evaluated according to Equations (5) and 7in 2017, amount to 503 and 356 gCO 2 / kWh El , respectively. 22 The lower value achieved by α TE F + RES is due to the contribution of RES-based electricity production. In Figure A1 the hourly correlation between η TE F + B and α TE F + B parameters is showed while in Figure A2 η Ã TE F + RES is plotted against the RESs penetration in electricity production on hourly basis.…”
Section: Evaluation Of Italian Electric Efficiency Indicators and Tmentioning
confidence: 99%
“…Due to the strategic position of the power industry in various countries, the efficiency evaluation of the power industry has always been a hot issue for many experts and scholars [10][11][12][13][14]. The data envelopment analysis (DEA) method has been evaluated since the first time in 1978 by the well-known American researchers Charnes, Cooper, and Rhodes, and became the most common method used.…”
Section: Theoretical Backgroundmentioning
confidence: 99%
“…In particular, the average yearly η PG El calculated on the basis of hourly Italian power grid efficiency amounts to 0.710 while the average annual α is equal to 356 gCO 2 /kWh El. [50].…”
Section: Elmentioning
confidence: 99%
“…• Scenario_MV (MV): that takes in two account the average monthly values of η PG El and α evaluated in [50] and summarized in Table 5 Table 5. Average monthly values of η PG El and α referred to Italian electricity production in 2017 [50]. The FIXED case is considered for both RS and PS, while the reaming five cases are analyzed only for PS.…”
Section: Elmentioning
confidence: 99%