2005
DOI: 10.1016/j.jse.2004.05.009
|View full text |Cite
|
Sign up to set email alerts
|

Elbow joint laxity after experimental radial head excision and lateral collateral ligament rupture: Efficacy of prosthetic replacement and ligament repair

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
49
0
9

Year Published

2005
2005
2024
2024

Publication Types

Select...
4
4

Relationship

1
7

Authors

Journals

citations
Cited by 95 publications
(59 citation statements)
references
References 29 publications
1
49
0
9
Order By: Relevance
“…The radial head is an important secondary valgus restraint [16,25] and can bear up to 60% of the load transmitted from the forearm [9]. The goals of treating radial head fractures are to restore stability, preserve motion, and maintain length of the radius.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…The radial head is an important secondary valgus restraint [16,25] and can bear up to 60% of the load transmitted from the forearm [9]. The goals of treating radial head fractures are to restore stability, preserve motion, and maintain length of the radius.…”
Section: Introductionmentioning
confidence: 99%
“…In the normally functioning elbow, the anterior band of the medial ulnar collateral ligament (MUCL) provides the primary stabilization against valgus force [6,12,16,23,32]. Transection of the anterior bundle alone is sufficient to create demonstrable instability on the application of a valgus force and abnormally high radiocapitellar pressures [28].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Biomechanical studies have also shown the importance of the radial head in varus and posterolateral stability of the elbow [25][26][27][28]. In the presence of a torn MCL, obvious valgus instability, and associated lesions of the LCL and coronoid process on the affected limb, radial head replacement arthroplasty should be performed to provide stability to the elbow [29].…”
Section: Discussionmentioning
confidence: 99%
“…The theoretic accuracy of the MATMI is 0.70 o in flexion, 0.35 o in deviation, and 0.47 o in rotation. 36 In our set-up position and torque were measured in radioulnar deviation, flexion-extension, and internal/external rotation. To make measurements unambiguous and to avoid right/left confusion radial deviation, dorsal flexion, and internal rotation were designated as positive.…”
Section: Methods For Testingmentioning
confidence: 99%