2021
DOI: 10.3389/fphy.2021.620331
|View full text |Cite
|
Sign up to set email alerts
|

Elastography Validity Criteria Definition Using Numerical Simulations and MR Acquisitions on a Low-Cost Structured Phantom

Abstract: MR Elastography is a novel technique enabling the quantification of mechanical properties in tissue with MRI. It relies on a three-step process that includes the generation of a mechanical vibration, motion capture using dedicated MR sequences, and data processing involving inversion algorithms. If not properly tuned to the targeted application, each of those steps may impact the final outcome, potentially causing diagnostic errors and thus eventually treatment mismanagement. Different approaches exist that ac… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
7
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(8 citation statements)
references
References 59 publications
1
7
0
Order By: Relevance
“…The latter showed increased shear stiffness measured in phantom compartment A compared to compartment B, as expected from their composition and manual palpation. Such values are within the range observed in a previous study with similar silicone compositions ( 29 ). In vivo results, on the other hand, clearly show waves propagating along the muscle orientation with a pattern that follows the anatomical structures.…”
Section: Discussionsupporting
confidence: 90%
See 3 more Smart Citations
“…The latter showed increased shear stiffness measured in phantom compartment A compared to compartment B, as expected from their composition and manual palpation. Such values are within the range observed in a previous study with similar silicone compositions ( 29 ). In vivo results, on the other hand, clearly show waves propagating along the muscle orientation with a pattern that follows the anatomical structures.…”
Section: Discussionsupporting
confidence: 90%
“…Overall, in our conditions, it is reasonable to favor acquisition acceleration by a factor of 10 and intrinsically discard high-frequency noise to obtain high SNR, which is key for reliable MRE ( 29 ), rather than to apply postprocessing filters to fully sampled scans. Filtering is quite common in MRE reconstruction pipelines, especially in those relying on spatial derivatives that are rather sensitive to noise ( 43 ).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…From an acquisition point of view, the quality of MRE data can be estimated from phase to noise ratio which in a first approximation is tied to the signal to noise ratio (SNR) and the encoded phase shift [25]. Obviously the SNR will critically rely on the acquisition parameters but also on the spin transverse relaxation time (T 2 *) of the tissue that can be really low for example in liver with iron overload [26] or in lungs [27] and lead to very low SNR.…”
Section: Physical and Acquisition Constraintsmentioning
confidence: 99%