2006
DOI: 10.1016/j.gie.2005.07.026
|View full text |Cite
|
Sign up to set email alerts
|

Elastic scattering spectroscopy for the diagnosis of colonic lesions: initial results of a novel optical biopsy technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
74
0

Year Published

2008
2008
2017
2017

Publication Types

Select...
7
3

Relationship

1
9

Authors

Journals

citations
Cited by 102 publications
(80 citation statements)
references
References 23 publications
2
74
0
Order By: Relevance
“…More advanced fibre optic probes for PLSS made use of gradient-index (GRIN) lens to implement depth selective measurement from a range of near surface depths (100-200 mm) to interrogate blood supply [66,67]. A great number of translational studies for diagnosis of breast cancer [68], prostate cancer [69], intraoperative determination of sentinel lymph node status in the breast [70], colonic lesions [71], oral premalignancy [72], high grade dysplasia and cancer in Barrett's oesophagus [73,74], cervix neoplasia [75,76], investigation of the nature of aceto-whitening in cervix cancer inspection [77][78][79][80][81][82], gold nanoparticle sizing [83], and monitoring apoptosis in cell cultures [84][85][86] have demonstrated that LSS provides a promising solution for cell culture monitoring, tissue surveillance and biopsy guidance in a relatively simple and cost effective configuration.…”
Section: Polarized Light and Biological Tissuementioning
confidence: 99%
“…More advanced fibre optic probes for PLSS made use of gradient-index (GRIN) lens to implement depth selective measurement from a range of near surface depths (100-200 mm) to interrogate blood supply [66,67]. A great number of translational studies for diagnosis of breast cancer [68], prostate cancer [69], intraoperative determination of sentinel lymph node status in the breast [70], colonic lesions [71], oral premalignancy [72], high grade dysplasia and cancer in Barrett's oesophagus [73,74], cervix neoplasia [75,76], investigation of the nature of aceto-whitening in cervix cancer inspection [77][78][79][80][81][82], gold nanoparticle sizing [83], and monitoring apoptosis in cell cultures [84][85][86] have demonstrated that LSS provides a promising solution for cell culture monitoring, tissue surveillance and biopsy guidance in a relatively simple and cost effective configuration.…”
Section: Polarized Light and Biological Tissuementioning
confidence: 99%
“…Three common spectroscopic techniques are Raman spectroscopy (RS), diffuse reflectance spectroscopy (DRS), and laser-induced fluorescence spectroscopy (LIFS). These techniques have been applied -either individually or in combinations -throughout the entire human body to investigate a wide range of pathologies including: atherosclerosis, 1, 2 osteoporosis, 3 brain edema, 4 cataract formation, 5 kidney stones, 6,7 and diabetes 8 and cancer of the breast, 9-11 cervix, 12 esophagus, 13,14 gastrointestinal tract, 15,16 brain, 17 lungs, 18,19 ovaries, 20 and bladder. 21 Here, we present a novel multimodal spectroscopy (MMS) device, combining RS, LIFS, and DRS, for the purpose of fast and non-invasive early detection of skin cancer which uses a variety of instrumentation and a custom contact probe capable of delivering and collecting light for all three modalities.…”
Section: Introductionmentioning
confidence: 99%
“…To obtain this information, optical techniques can take advantage of the very distinct absorption features of oxygenated (oxy-) and deoxygenated (deoxy-) hemoglobin (Hb), and have the ability to provide noninvasive, in-vivo monitoring. However, current optical techniques for this purpose, including pulse oximetry, elastic light spectroscopy [2], diffuse reflectance spectroscopy [3], and differential path length spectroscopy [4], suffer from poor spatial resolution, thus only obtaining tissue properties averaged over large volumes. These methods are also unable to obtain precise information regarding the trajectories of the measured photons; as a result, parameters of interest, including absorption, are estimated by employing empirical and/or Monte Carlo simulations rather than physical models.…”
Section: Introductionmentioning
confidence: 99%