2013
DOI: 10.1016/j.remnie.2013.09.003
|View full text |Cite
|
Sign up to set email alerts
|

Elaboration of the SPM template for the standardization of SPECT images with 123I-Ioflupane

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
26
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(26 citation statements)
references
References 11 publications
0
26
0
Order By: Relevance
“…were masked out for both molecular atlases as they were used as reference regions for the quantification of the molecular data in the kinetic models for the radioligands. For more details on the molecular templates, please refer to [45,46].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…were masked out for both molecular atlases as they were used as reference regions for the quantification of the molecular data in the kinetic models for the radioligands. For more details on the molecular templates, please refer to [45,46].…”
Section: Resultsmentioning
confidence: 99%
“…For the analysis with REACT, we used molecular templates of the DAT and NET systems. The DAT map is a publicly available template of 123 I-Ioflupane SPECT images (https://www.nitrc.org/projects/spmtemplates) from 30 HC without evidence of nigrostriatal degeneration [45]. The NET atlas was obtained by averaging the [ 11 C]MRB PET brain parametric maps from an independent dataset of 10 HC (33.3 +/-10 years, four women).…”
Section: Population-based Molecular Templatesmentioning
confidence: 99%
“…103 patients had a high-resolution Magnetization Prepared Rapid Gradient Echo (MPRAGE) 3DT1brain scan performed on 3.0 Tesla MR system (Magnetom Trio, Siemens, Erlangen Germany) as part of our clinical routine protocol (256 × 256 matrix, 176 sections, 1 × 1 × 1 mm 3 , TE = 2.3 ms, TR = 2300 ms). This subsample was used to build a 123 I-ioflupane SPECT template in Montreal Neurological Institute (MNI) standard space as described earlier ( Badoud et al, 2016 , García-Gómez et al, 2013 ).…”
Section: Methodsmentioning
confidence: 99%
“…We used a 123 I-ioflupane SPECT template in Montreal Neurological Institute (MNI) standard space as described earlier ( Badoud et al, 2016 , García-Gómez et al, 2013 ) in an automatic and operator-independent workflow. Due to the asymmetrical degeneration of the nigrostriatal pathways in PD and APS, we decided to flip all patients presenting predominant clinical symptoms on the left side of the body in order to obtain a more homogeneous sample with dominant symptomatology always at the same hemisphere.…”
Section: Methodsmentioning
confidence: 99%
“…For the main analyses, cerebellum-corrected Ki values were extracted from a striatal region of interest defined independently from an [ 18 F]DOPA PET template normalized to MNI space (García-Gómez et al, 2013). In order to improve sensitivity, we retained the template voxels in which Ki values exceeded the mean Ki value across all voxels by at least 3 standard deviations ( Figure 1A).…”
Section: Pet Data Preprocessing and Analysesmentioning
confidence: 99%