2009
DOI: 10.1016/j.tet.2009.05.051
|View full text |Cite
|
Sign up to set email alerts
|

Efficient synthesis of phosphonodepsipeptides derived from norleucine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 14 publications
(11 citation statements)
references
References 50 publications
0
11
0
Order By: Relevance
“…The structure of the selector (Figure ) was confirmed by NMR spectroscopy performed on an Agilent 400‐MR DDR2 spectrometer operating at 400.13 MHz for 1 H and 100.62 MHz for 13 C. The selector coverage was determined (based on nitrogen content) from elemental analysis performed on a Perkin‐Elmer 2400 instrument. Racemic analytes used for the evaluation of the CSPs (Figure ) were synthesized according to published procedures , for details see Supporting Information. Structures of the selector and analytes were drawn in ISIS draw (MDL Information Systems, Hayward, CA, USA).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The structure of the selector (Figure ) was confirmed by NMR spectroscopy performed on an Agilent 400‐MR DDR2 spectrometer operating at 400.13 MHz for 1 H and 100.62 MHz for 13 C. The selector coverage was determined (based on nitrogen content) from elemental analysis performed on a Perkin‐Elmer 2400 instrument. Racemic analytes used for the evaluation of the CSPs (Figure ) were synthesized according to published procedures , for details see Supporting Information. Structures of the selector and analytes were drawn in ISIS draw (MDL Information Systems, Hayward, CA, USA).…”
Section: Methodsmentioning
confidence: 99%
“…Modification of silica materials and immobilization of the selector is described in Supporting Information (SI). The structure of the selector (Figure 1) was confirmed by NMR spectroscopy performed on an Agilent 400-MR DDR2 spectrometer operating at 400.13 MHz for 1 H and 100.62 MHz for 13 C. The (Figure 2) were synthesized according to published procedures [37], for details see Supporting Information. Structures of the selector and analytes were drawn in ISIS draw (MDL Information Systems, Hayward, CA, USA).…”
Section: Chemicals and Analytesmentioning
confidence: 99%
“…High resolution mass spectra (HRMS) were obtained on a Fourier transform mass spectrometer (FTMS) LTQ-orbitrap XL (Thermo Fisher, Bremen, Germany) in the electrospray ionisation mode. Reverse phase HPLC (RP-HPLC) purification of the target compounds was performed as described previously by Pícha et al [38]. All chemicals were of analytical grade, obtained from commercial suppliers (Sigma-Aldrich and Fluka, Prague, Czech Republic and Poznań, Poland, Merck, Darmstadt, Germany, POCh, Gliwice, Poland) and were used without further purification.…”
Section: Generalmentioning
confidence: 99%
“…The phosphonic analogue of norleucine (3, Nle-P) was obtained from the respective aldehyde as described by Pícha et al [38,40]. The syntheses of the phosphinic compounds Met-PH (2), Nle-PH (4) and Met-ψ[P(O)(OH)CH 2 ]-Ala (5) were recently published elsewhere and we have only provided the detailed physico-chemical characteristics that weren′t reported in our previous communication here [41].…”
Section: Synthesismentioning
confidence: 99%
See 1 more Smart Citation