2005
DOI: 10.1021/ol050027t
|View full text |Cite
|
Sign up to set email alerts
|

Efficient Immobilization of a Cadmium Chemosensor in a Thin Film:  Generation of a Cadmium Sensor Prototype

Abstract: [reaction: see text] The development of an ion-selective chemosensor for Cd(2+) allows generation of a "real-time" sensor. Immobilization of the chemosensor on quartz was achieved in a simple monolayer and in a thin film using a polymer intermediary. As intended, the thin film contains much more chemosensor than the monolayer and provides measurable responses to aqueous Cd(2+) concentrations below 1 microM. Alkali and alkaline earth ions do not interfere with Cd(2+) sensing; Zn(2+) and Cu(2+) are potential int… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
37
1

Year Published

2006
2006
2016
2016

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 124 publications
(40 citation statements)
references
References 14 publications
0
37
1
Order By: Relevance
“…45 nM). Although the LOD for Cd 2+ in this study does not meet the requirement by EPA, it is comparable to that of a thin film Cd 2+ chemosensor (1.0 M) [49] and much lower than that of laser induced breakdown spectroscopy technique (500 mg L −1 , i.e. 4.5 × 10 −3 M) [50].…”
Section: Detection Of Zn 2+ and CD 2+ Based On S 2− Modified Cdte Qdscontrasting
confidence: 62%
“…45 nM). Although the LOD for Cd 2+ in this study does not meet the requirement by EPA, it is comparable to that of a thin film Cd 2+ chemosensor (1.0 M) [49] and much lower than that of laser induced breakdown spectroscopy technique (500 mg L −1 , i.e. 4.5 × 10 −3 M) [50].…”
Section: Detection Of Zn 2+ and CD 2+ Based On S 2− Modified Cdte Qdscontrasting
confidence: 62%
“…Methods for immobilizing proteins on gold film, which have been investigated for years, include the SPA method (15,23 ), the avidin and biotin method (24,25 ), and the self-assembled monolayers method (26,27 ). The SPA method was adopted in the present experiment because it can create more reproducible and stable immobilization layers with less added mass for IgG coating (28 ).…”
Section: Results and Discussion Optimization Of Immobilized Antibody mentioning
confidence: 99%
“…For quenching of FL intensity in the presence of Hg 2+ ion, the reason maybe attribute to the effect between heavy metal ions such as Hg 2+ (4f 14 5d 10 ), Pb 2+ (4f 14 6d 10 ) and Au + (4f 14 5d 10 ) [18,[27][28][29][30]. That is, BSA macromolecules, which contains lots of amino or carbonyl C=O group/ s in the skeleton/surface [31], and Cd 2+ ion has much stronger affinity for nitrogen/oxygen atoms of amino or carbonyl C=O group/s ( Figure S7) [32][33][34][35]. And assuming amino or carbonyl C=O group/s produce a moderate quenching to the FL BSA-Au-Ni NCs by PET.…”
Section: Optimization Of Methodsmentioning
confidence: 99%