Efficiency optimization of wireless power transmission systems for active capsule endoscopes

Abstract: Multipurpose active capsule endoscopes have drawn considerable attention in recent years, but these devices continue to suffer from energy limitations. A wireless power supply system is regarded as a practical way to overcome the power shortage problem in such devices. This paper focuses on the efficiency optimization of a wireless energy supply system with size and safety constraints. A mathematical programming model in which these constraints are considered is proposed for transmission efficiency, optimal fr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
38
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 40 publications
(41 citation statements)
references
References 22 publications
0
38
0
Order By: Relevance
“…Although, the intensity of the generated magnetic field depends on the magnitude of the TC driving signal, the uniformity of the field depends completely on the type and the design structure of the TC [64]. In general, they are two types of TC which include solenoid coils [12,36,61–63,6569] and Helmholtz coils [30,33,70]. The solenoid coil can be arranged in four different forms: (i) single solenoid [65]; (ii) a pair of solenoids [67]; (iii) a pair of double layer solenoids [12] and (iv) segmented solenoids [63].…”
Section: Wpt System For Wcementioning
confidence: 99%
See 3 more Smart Citations
“…Although, the intensity of the generated magnetic field depends on the magnitude of the TC driving signal, the uniformity of the field depends completely on the type and the design structure of the TC [64]. In general, they are two types of TC which include solenoid coils [12,36,61–63,6569] and Helmholtz coils [30,33,70]. The solenoid coil can be arranged in four different forms: (i) single solenoid [65]; (ii) a pair of solenoids [67]; (iii) a pair of double layer solenoids [12] and (iv) segmented solenoids [63].…”
Section: Wpt System For Wcementioning
confidence: 99%
“…The commonly used ferrite cores are 3F4 of Ferroxcube (μi = 1000) [71], R5K (μi = 5000) [62] or R10K (μi = 10,000) [12] of DMEGC Magnetic Co., Ltd., Zhejiang, China.…”
Section: Wpt System For Wcementioning
confidence: 99%
See 2 more Smart Citations
“…All these characteristics greatly increase the design difficulty of the WPT system of CE, particularly for the RX unit. In the past decade, many WPT systems for CE have been developed and the received power could be up to several hundreds of milliwatt [8][9][10][11][12]. However, the design parameters of these systems were always determined by experiments, which are time-consuming and easily disturbed by environment.…”
Section: Introductionmentioning