2019
DOI: 10.15802/bttrp2019/189428
|View full text |Cite
|
Sign up to set email alerts
|

Efficiency of Thin-Walled Galvanized Profiles for Arch Elements

Abstract: 1 Факультет «Промислове та цивільне будівництво», Дніпровський національний університет залізничного транспорту імені академіка В. Лазаряна, вул. Лазаряна, 2, Дніпро, Україна, 49010, тел. +38 (063) 764 68 95, ел. пошта bezsalyslava@gmail.com, ORCID 0000-0003-4424-0105 2* Кафедра «Будівельне виробництво та геодезія», Дніпровський національний університет залізничного транспорту імені академіка В. Лазаряна, вул. Лазаряна, 2, Дніпро, Україна, 49010, тел. +38 (063) 400 43 07, ел. пошта bdo2020@yahoo.com, ORCID 000… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 5 publications
0
1
0
Order By: Relevance
“…The absence of tie-beams between arches always leads to overspending of materials for the construction of building foundations. For some light arched buildings, for example, frameless ones [21,22], made of profiled sheeting, combining both enclosing and bearing functions, the use of tie-beams is one of the prerequisites for the possibility of their use with sufficiently large spans in areas with significant snow load. Scientists of Kazan state university of architecture and engineering (KSUAE) proposed structural solutions (see Figs.…”
Section: Methodsmentioning
confidence: 99%
“…The absence of tie-beams between arches always leads to overspending of materials for the construction of building foundations. For some light arched buildings, for example, frameless ones [21,22], made of profiled sheeting, combining both enclosing and bearing functions, the use of tie-beams is one of the prerequisites for the possibility of their use with sufficiently large spans in areas with significant snow load. Scientists of Kazan state university of architecture and engineering (KSUAE) proposed structural solutions (see Figs.…”
Section: Methodsmentioning
confidence: 99%
“…Також автори в свій час вже звертались до даної проблеми в ході своїх досліджень, а отримані результати представлені в роботах [5][6][7]. При цьому було виявлено, що в сталевих конструкціях наявні певні резерви несучої здатності, що дійсно дозволяє підвищити ефективність її використання в сталевих будівельних конструкціях.…”
unclassified