2009
DOI: 10.1016/j.memsci.2008.09.044
|View full text |Cite
|
Sign up to set email alerts
|

Efficiency of MS2 phage and Qβ phage removal by membrane filtration in water treatment: Applicability of real-time RT-PCR method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

5
37
0
1

Year Published

2010
2010
2020
2020

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 85 publications
(43 citation statements)
references
References 21 publications
5
37
0
1
Order By: Relevance
“…HERATH et al (1999) ont ainsi montré que l'élimination des coliphages par microfiltration était liée à leurs charges électrostatiques et leurs points isoélectriques. Ce processus dépend donc des propriétés physico-chimiques des microorganismes et des adsorbants (BUSSCHER et al, 2008;LANGLET et al, 2009;RIzzO et al, 2008). Par ailleurs, les procédés de traitement par exclusion stérique seuls (filtration) peuvent s'avérer peu efficaces dans la rétention des virus en raison de leur faible taille, comprise entre 100 et 20 nm environ (FIKSDAL et LEIKNES, 2006).…”
Section: La Diversité Des Espèces Microbiennes Dans L'eau Potableunclassified
“…HERATH et al (1999) ont ainsi montré que l'élimination des coliphages par microfiltration était liée à leurs charges électrostatiques et leurs points isoélectriques. Ce processus dépend donc des propriétés physico-chimiques des microorganismes et des adsorbants (BUSSCHER et al, 2008;LANGLET et al, 2009;RIzzO et al, 2008). Par ailleurs, les procédés de traitement par exclusion stérique seuls (filtration) peuvent s'avérer peu efficaces dans la rétention des virus en raison de leur faible taille, comprise entre 100 et 20 nm environ (FIKSDAL et LEIKNES, 2006).…”
Section: La Diversité Des Espèces Microbiennes Dans L'eau Potableunclassified
“…Overall the application of these technologies faces some limitations that include their inability to remove ionic species and nano-sized particles such as viruses. water-borne microorganisms to remove (Langlet et al, 2009). The virion of most enteric viruses consists of nucleic acid genome encapsulated by a capsid composed of proteins containing weak acid and base groups (e.g., carboxyl, sulfhydril and amine groups) that are ionizable (Brown and Sobsey, 2009).…”
Section: Membrane Technology For Water Treatmentmentioning
confidence: 99%
“…A low isoelectric point indicates a high net negative charge on the virus surface at typical pH values of natural water. Langlet et al, (2009) discussed the physicochemical characteristics of MS2 phage, identifYing it as a worst-case scenario for the evaluation of virus removal by membrane filtration (i.e., (i) small size, (ii) high negative surface charge and (iii) high degree of hydrophobicity).…”
Section: Virus Analysismentioning
confidence: 99%
“…If the removal and inactivation of FRNAPH genotypes could be separately evaluated, the fate of the virus in the water environment or during the water treatment process would be better understood. Currently, the quantitative detection of Fϩ coliphages is done by plaque (culture) or reverse transcriptionquantitative PCR (RT-qPCR) assays (17)(18)(19)(20)(21)(22). The plaque assay can detect infectious phages but requires an immense effort for quantitative typing (23).…”
mentioning
confidence: 99%