2020
DOI: 10.1049/iet-gtd.2019.1408
|View full text |Cite
|
Sign up to set email alerts
|

Efficiency of different optimisation approaches for optimal parameters of the CSM for investigating the onset field due to corona point

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 46 publications
0
6
0
Order By: Relevance
“…With the increase of these electric fields in the presence of the air voids in the structure of the solid insulation layer, the solid insulation material will be exposed to the formation of the conductive cracks. These formed cracks resemble the shape of tree branches as a realistic embodiment of the electrical treeing phenomenon (ETP) [1][2][3][4].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…With the increase of these electric fields in the presence of the air voids in the structure of the solid insulation layer, the solid insulation material will be exposed to the formation of the conductive cracks. These formed cracks resemble the shape of tree branches as a realistic embodiment of the electrical treeing phenomenon (ETP) [1][2][3][4].…”
Section: Introductionmentioning
confidence: 99%
“…As the non-uniform electric fields play a vital role in the ET inception and growth, the researchers seek seriously to the accurate calculation and distribution of these fields. They realised the complexity of the calculation of these fields by using the traditional methods so the numerical methods are the best approaches to be used [1,2,[13][14][15][16].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The complete study of High Voltage (HV) and Extra High Voltage (EHV) complicated dangerous issues or phenomena in the generation, transmission and distribution systems is nowadays considered as an open challenge for researchers to either discover more hidden secrets or improve the methodologies to enhance the features of the power system networks in the presence of these harmful phenomena [1][2][3][4][5][6][7]. One of the most effective and common studies that are related to these HV and EHV phenomena is the accurate distribution of electric and magnetic fields and their calculation methodologies that affect and control directly the severity degree of these issues on the quality and service continuity of the different power system networks [8].…”
Section: Introductionmentioning
confidence: 99%
“…Due to the heat treatments and sudden cooling processes, The solid insulation is extremely exposed to the formation of air voids in the manufacturing. The presence of both air voids of the solid dielectric around the conducting wire and the initiated conducting protrusions through the conductor under abnormal operational modes will lead to the excessive generation of the nonuniform electric fields and the initiation or propagation of Electrical Tree (ET) [1][2][3][4]. It is necessary to show that the term Electrical Treeing is associated with the theoretical concept of ETP unlike the term Electrical Tree that is associated with the actual configurable representation of ETP so, it is commonly said that ET is the realistic embodiment of ETP .…”
Section: Introductionmentioning