Efficiency estimates of a stream Benthos suction sampler

Abstract: The efficiency of a modified Boulton suction sampler was tested in 2 riffle zones, using multiple removals. Macroinvertebrate fauna was sampled with approximately 70% efficiency on first removal, while organic matter was sampled with 55% efficiency. Sampling efficiencies for specific taxa ranged from 86% (Plecoptera) to 66% (Chironomidae) and 59% (Trichoptera). The results of this study indicate that sampling efficiency can be improved either by taking multiple samples at one location or by increasing the time… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

1994
1994
2000
2000

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…Macroinvertebrate communities were sampled at the eight sites on 12 occasions between November 1988 and July 1990, except that Sites C1 and C2 were not sampled in January 1989 owing to equipment failure. Six replicate benthic samples were taken randomly from each site on each sampling occasion with a modified Boulton (1985) sampler (see Growns 1990). Macroinvertebrate samples were stored in 70% ethanol until they were sorted.…”
Section: Methodsmentioning
confidence: 99%
“…Macroinvertebrate communities were sampled at the eight sites on 12 occasions between November 1988 and July 1990, except that Sites C1 and C2 were not sampled in January 1989 owing to equipment failure. Six replicate benthic samples were taken randomly from each site on each sampling occasion with a modified Boulton (1985) sampler (see Growns 1990). Macroinvertebrate samples were stored in 70% ethanol until they were sorted.…”
Section: Methodsmentioning
confidence: 99%
“…One technique is to estimate the population by taking repeated samples from one location until most or all animals have been collected (Southwood, 1978) . Sampler efficiency has been expressed as the percentage of the total number of individuals caught in consecutive samples that were removed in the first sample (Brown et al ., 1987 ;Growns, 1990) . However, these specific estimates are of limited use because they depend entirely on the duration of each sample, the effort expended by the operator and the prevailing physical conditions (e .g .…”
Section: Efficiency Estimatesmentioning
confidence: 99%