“…Using D = 53%, a turns-ratio of approximately 4.2 is obtained from (1). Using (2) the maximum reverse voltage in the secondary rectifier (Vds_SRmax) can be calculated, which is especially important if a synchronous rectification switch is used to improve the efficiency, as in this case [22] - [24].…”
Section: Parameter Valuementioning
confidence: 99%
“…Using D = 53%, a turns-ratio of approximately 4.2 is obtained from (1). Using (2) the maximum reverse voltage in the secondary rectifier (Vds_SRmax) can be calculated, which is especially important if a synchronous rectification switch is used to improve the efficiency, as in this case [22] - [24].…”
Section: Parameter Valuementioning
confidence: 99%
“…There are a few methods to improve the flyback converter efficiency. The synchronous rectification can be adopted in cases of high-output currents to reduce voltage drop on the output rectifier [12][13][14]. The active clamp [6,15] or inductor-capacitor snubber circuit design [16,17] can be used to improve efficiency at cases of high primary spike losses.…”
Section: Introductionmentioning