Efficacy of Transosseous Tunnel Placement for Triple Endobutton Plate in Acromioclavicular Joint Reconstruction: A Three‐Dimensional Printing Guide Design Technology

Abstract: Objective: Explore an accurate transosseous tunnel drilling method based on three-dimensional (3D) printing technology for acromioclavicular joint reconstruction (ACD), design a guide design, and evaluate its accuracy.Methods: Using Mimics software to reconstruct 100 cases of acromioclavicular joint computed tomography (CT) data.In design 2, the non-collinear tunnel is superimposed on the 3D model, and a virtual drilling is performed between the clavicle and the coracoid using a triple inner gusset. Then, in t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
0
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 26 publications
0
0
0
Order By: Relevance
“…9 The results of this study seem to confirm the conclusions of Coale et al 9 Surgeons 18 Navigation did not require any readjustments, but drill misguidance and cortical breaches were observed in 2 cases (20%) with the standard technique. Custom-made drill guides using 3-dimensional (3D) printing have been developed by Zhang et al 19 Based on computed tomography images, 3D-printing software was used to create drill guides for transclavicularetranscoracoid tunnel drilling, and they have demonstrated an accuracy of 0.1 mm for 10 measured parameters when assessing tunnel placement in a virtual 3D shoulder model. 19 Central coracoid tunnel placement and projection seems critical to avoid complications.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…9 The results of this study seem to confirm the conclusions of Coale et al 9 Surgeons 18 Navigation did not require any readjustments, but drill misguidance and cortical breaches were observed in 2 cases (20%) with the standard technique. Custom-made drill guides using 3-dimensional (3D) printing have been developed by Zhang et al 19 Based on computed tomography images, 3D-printing software was used to create drill guides for transclavicularetranscoracoid tunnel drilling, and they have demonstrated an accuracy of 0.1 mm for 10 measured parameters when assessing tunnel placement in a virtual 3D shoulder model. 19 Central coracoid tunnel placement and projection seems critical to avoid complications.…”
Section: Discussionmentioning
confidence: 99%
“…Custom-made drill guides using 3-dimensional (3D) printing have been developed by Zhang et al 19 Based on computed tomography images, 3D-printing software was used to create drill guides for transclavicularetranscoracoid tunnel drilling, and they have demonstrated an accuracy of 0.1 mm for 10 measured parameters when assessing tunnel placement in a virtual 3D shoulder model. 19 Central coracoid tunnel placement and projection seems critical to avoid complications. Ferreira et al 20 have investigated tunnel trajectory and demonstrate that superior center-to-inferior center or superior medial-to-inferior central tunnel orientation reduces the risk of coracoid fracture.…”
Section: Discussionmentioning
confidence: 99%
“…Reducción y fijación de la luxación acromioclavicular con la técnica de doble túnel por medio de guía quirúrgica a medida 98,99 Adquisición de la imagen: TAC Segmentación:…”
Section: Abs Medical Esterilización Con óXido De Etilenounclassified