2019
DOI: 10.1177/2041731419852703
|View full text |Cite
|
Sign up to set email alerts
|

Efficacy of copolymer scaffolds delivering human demineralised dentine matrix for bone regeneration

Abstract: Poly(L-lactide-co-ε-caprolactone) scaffolds were functionalised by 10 or 20 µg/mL of human demineralised dentine matrix. Release kinetics up to 21 days and their osteogenic potential on human bone marrow stromal cells after 7 and 21 days were studied. A total of 390 proteins were identified by mass spectrometry. Bone regeneration proteins showed initial burst of release. Human bone marrow stromal cells were cultured on scaffolds physisorbed with 20 µg/mL and cultured in basal medium (DDM group) or physisorbed … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
16
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 16 publications
(16 citation statements)
references
References 47 publications
(68 reference statements)
0
16
0
Order By: Relevance
“…Interactions between cytokines were analyzed using the Search Tool for the Retrieval of Interacting Genes/Proteins (STRING) database and online software [ 19 ]. Cytokines were clustered according to the Markov Cluster algorithm and the STRING global score as previously reported [ 20 ].…”
Section: Methodsmentioning
confidence: 99%
“…Interactions between cytokines were analyzed using the Search Tool for the Retrieval of Interacting Genes/Proteins (STRING) database and online software [ 19 ]. Cytokines were clustered according to the Markov Cluster algorithm and the STRING global score as previously reported [ 20 ].…”
Section: Methodsmentioning
confidence: 99%
“…Control PLGA and PLGA/MH composites were placed in vials containing 1 ml of PBS solution in a shaking water bath under physiological conditions (pH 7.4, 100 rpm and 37°C). At predetermined time points (1,3,5,7,14,21,28,35,42,49, and 56 days), pH level was determined via pH-meter (Mettler Toledo, Ohio, USA). For the residual mass percentage determination, the film was cut (3 × 7 mm), initially weighted (W 0 ), immersed in PBS solution for a predetermined time, washed by deionized water, dried under vacuum for 2 days, and finally weighed (W t ).…”
Section: Characterizations Of the Plga/mh Compositementioning
confidence: 99%
“…The BMP2 loaded onto control PLGA and PLGA/MH composites was immersed in 4 M Guanidine-HCI and protease inhibitors. It followed the assay procedure and at predetermined time (1,3,5,7,14,21,28,35,42,49, and 56 days), the amount of released BMP2 was determined.…”
Section: Characterizations Of the Plga/mh Compositementioning
confidence: 99%
See 2 more Smart Citations