2002
DOI: 10.1016/s0010-7824(02)00345-1
|View full text |Cite
|
Sign up to set email alerts
|

Efficacy of a mini version of the frameless GyneFix intrauterine system (IUS) with effective copper surface area of 200 mm2

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2003
2003
2009
2009

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(9 citation statements)
references
References 3 publications
0
9
0
Order By: Relevance
“…These include a mini-GyneFix (the GF200 ® ) with a copper surface area of just 200 mm 2 , and GynePlant ® (a frameless device containing both copper and levonorgestrel). 20,21 Conclusions Although this study does not show the GyneFix to be superior to the Gyne-T380S for ease of insertion or discomfort, it does suggest that pain is less subsequent to insertion, accounting for higher continuation rates. The high overall continuation rate of both emergency IUDs at 6 weeks and the low morbidity seen in this study, plus its higher efficacy over oral EC, should encourage us to offer IUD insertion more often where unprotected intercourse has occurred.…”
Section: Description Of Pain Insertionmentioning
confidence: 57%
“…These include a mini-GyneFix (the GF200 ® ) with a copper surface area of just 200 mm 2 , and GynePlant ® (a frameless device containing both copper and levonorgestrel). 20,21 Conclusions Although this study does not show the GyneFix to be superior to the Gyne-T380S for ease of insertion or discomfort, it does suggest that pain is less subsequent to insertion, accounting for higher continuation rates. The high overall continuation rate of both emergency IUDs at 6 weeks and the low morbidity seen in this study, plus its higher efficacy over oral EC, should encourage us to offer IUD insertion more often where unprotected intercourse has occurred.…”
Section: Description Of Pain Insertionmentioning
confidence: 57%
“…The high initial and ongoing effectiveness of the ‘anchored device’ is attributed to its constant release of spermicidal copper ions in the upper part of the uterine cavity. This may explain why clinical trials with the mini IUS suggest a similar efficacy as the standard IUS 13 …”
Section: Efficacymentioning
confidence: 94%
“… High efficacy, 6–9,11 , 13,17–21 Efficacy does not decrease with time, 6,7 , 9,11 Low expulsion rate, 6–9,11 , 17–21 Reduced bleeding, 13 Reduced pain complaints, 7,8 , 11,13 , 17,22 Long duration of action 9 …”
Section: Potential Advantages Of the Frameless Copper‐releasing Ius Omentioning
confidence: 99%
See 2 more Smart Citations