ObjectiveRadiofrequency ablation (RFA) uses the heat generated by a high‐frequency alternating electric current, and according to Ohm's and Joule's law, the delivered current is inversely proportional to the circuit impedance. The primary objective of this study was to investigate whether tissue impedance during radiofrequency ablation (RFA) for benign thyroid nodules is related to the degree of volume reduction.MethodsThis observational study included consecutive patients treated with RFA for benign thyroid nodules from February 2020 to August 2023. Technical effectiveness was defined as a volume reduction percentage (VRP) >75% at 6 months after the treatment. Multivariate logistic regression analyses were performed to identify the potential role of clinical factors and changes in tissue impedance on technique effectiveness.ResultsTotally 72 patients were included with 73 benign thyroid nodules. Maximal impedance peaks reached <18 times, and mean procedural impedance ≤300 Ω were significantly associated with a volume decrease of >75% at bivariate analysis. These cutoff points were exploratory, as no existing literature suggests these variables are related to the degree of volume reduction. After adjusting for age, volume, and composition, significant associations were found for mean electrical impedance in the multivariate analysis (OR = 4.86 [confidence interval [CI] 1.29–18.26], p = 0.019). The energy adjusted by volume (delivered energy) was not associated with a VRP >75% (p = 0.7746).ConclusionsThis study suggests that a mean procedural impedance </= 300 Ω is related to the effectiveness of RFA as measured by VRP. Additional prospective and randomized studies are needed to compare electrical parameters with VRP.Level of Evidence3 Laryngoscope, 2024
ObjectiveRadiofrequency ablation (RFA) uses the heat generated by a high‐frequency alternating electric current, and according to Ohm's and Joule's law, the delivered current is inversely proportional to the circuit impedance. The primary objective of this study was to investigate whether tissue impedance during radiofrequency ablation (RFA) for benign thyroid nodules is related to the degree of volume reduction.MethodsThis observational study included consecutive patients treated with RFA for benign thyroid nodules from February 2020 to August 2023. Technical effectiveness was defined as a volume reduction percentage (VRP) >75% at 6 months after the treatment. Multivariate logistic regression analyses were performed to identify the potential role of clinical factors and changes in tissue impedance on technique effectiveness.ResultsTotally 72 patients were included with 73 benign thyroid nodules. Maximal impedance peaks reached <18 times, and mean procedural impedance ≤300 Ω were significantly associated with a volume decrease of >75% at bivariate analysis. These cutoff points were exploratory, as no existing literature suggests these variables are related to the degree of volume reduction. After adjusting for age, volume, and composition, significant associations were found for mean electrical impedance in the multivariate analysis (OR = 4.86 [confidence interval [CI] 1.29–18.26], p = 0.019). The energy adjusted by volume (delivered energy) was not associated with a VRP >75% (p = 0.7746).ConclusionsThis study suggests that a mean procedural impedance </= 300 Ω is related to the effectiveness of RFA as measured by VRP. Additional prospective and randomized studies are needed to compare electrical parameters with VRP.Level of Evidence3 Laryngoscope, 2024
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.