2015
DOI: 10.1007/s12663-015-0807-0
|View full text |Cite
|
Sign up to set email alerts
|

Efficacy and Versatility of the 3-D Titanium Mesh Implant in the Closure of Large Post-Craniectomy Osseous Defects, and its Therapeutic Role in Reversing the Syndrome of the Trephined: Clinical Study of a Case Series and Review of Literature

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
10
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(11 citation statements)
references
References 36 publications
(36 reference statements)
1
10
0
Order By: Relevance
“…The overall histological and radiographic results show a survival and success rate of 100% according to Albrektsson et al . 27 , confirming our previous hypothesis that the combination of Bio-Gide membrane and titanium mesh may achieve an enhanced bone regeneration effect.…”
Section: Discussionsupporting
confidence: 89%
See 1 more Smart Citation
“…The overall histological and radiographic results show a survival and success rate of 100% according to Albrektsson et al . 27 , confirming our previous hypothesis that the combination of Bio-Gide membrane and titanium mesh may achieve an enhanced bone regeneration effect.…”
Section: Discussionsupporting
confidence: 89%
“…13 reported the use of titanium mesh in GBR to repair severe alveolar defects at implant sites. Recently, the use of a rigid titanium mesh, stabilized as a tent over a resorbed ridge in full/partial restoration of the alveolar process, has been reported 14 , 15 . The porous titanium mesh can cover the alveolar defects to form the ideal shape of the alveolar ridge, thus effectively preventing soft tissue collapse and displacement of bone particles during bone regeneration 16 , 17 .…”
Section: Introductionmentioning
confidence: 99%
“…Previous methods of cranioplasty in dogs are not ideal and recently the use of titanium mesh has been described in a small subset of dogs with good outcomes [1]. In humans it has been shown that titanium mesh can provide a safe and reliable implant that allows for postoperative CT and magnetic resonance imaging [13]. Despite this benefit, it does not always provide a cosmetic solution or one that reduces surgery time, speeds healing, or improves clinical outcome [6,8,9].…”
Section: Discussionmentioning
confidence: 99%
“…Compared to alloplastic materials, autogenous calvarial bone grafts present better mechanical, biological, and immunological characteristics (13) . Nevertheless, titanium mesh implant is an alternative to calvarial grafts, especially in cases with large cranial defects, as it is inert, malleable and has the ability to osseointegrate (14) . Additionally, advanced 3D printing techniques have permitted the manufacturing of porous titanium implants, customised to the individual needs of patients with such defects, without leaving any dead space, but at a rather high cost (15) .…”
Section: Discussionmentioning
confidence: 99%