Efficacy and safety of balloon-assisted microdissection with Sapphire® II 1.0-mm balloon in balloon-uncrossable chronic total occlusion lesions

Abstract: Objective Earlier studies have shown that the balloon-assisted microdissection (BAM) technique is feasible using a 1.2- to 1.5-mm small balloon in balloon-uncrossable chronic total occlusion (CTO) lesions. This study was performed to assess the efficacy and safety of the BAM technique with a Sapphire® II 1.0-mm balloon. Methods In this retrospective study, patients undergoing percutaneous coronary intervention for CTO were consecutively screened for balloon-uncrossable CTO lesions using BAM with the Sapphire® … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 17 publications
0
2
0
Order By: Relevance
“…In a retrospective study by Ye et al, the efficacy and safety of the BAM technique were assessed in 24 balloon uncrossable CTOs with the Sapphire ® II 1.0 mm balloon (OrbusNeich, Hong Kong, China). The technical success rate was 75% (18/24) for the lesions successfully treated with BAM, with a total technical success rate of 92% (22/24; when BAM failed, 2 patients were successfully treated with laser and 2 with rotational atherectomy) [ 30 ].…”
Section: Discussionmentioning
confidence: 99%
“…In a retrospective study by Ye et al, the efficacy and safety of the BAM technique were assessed in 24 balloon uncrossable CTOs with the Sapphire ® II 1.0 mm balloon (OrbusNeich, Hong Kong, China). The technical success rate was 75% (18/24) for the lesions successfully treated with BAM, with a total technical success rate of 92% (22/24; when BAM failed, 2 patients were successfully treated with laser and 2 with rotational atherectomy) [ 30 ].…”
Section: Discussionmentioning
confidence: 99%
“…In our case, we assumed that the complication was due to the grenadoplasty technique. This technique, also known as balloon-assisted microdissection, is a relatively safe plaque modification method for balloon uncrossable lesions by intentional balloon rupture [ 4 ]. However, the complications were detected early; hence, preventive measures for worsening conditions were performed.…”
Section: Discussionmentioning
confidence: 99%