2017
DOI: 10.21454/rjaic.7518.242.ber
|View full text |Cite
|
Sign up to set email alerts
|

Efficacy and duration of ultrasound guided fascia iliaca block for hip fracture performed in the emergency departments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
4
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 8 publications
(9 reference statements)
0
4
1
Order By: Relevance
“…While there were no differences in delirium by FICB status, it was interesting to find that patients who developed delirium were more likely to receive a second block than those who did not develop delirium (18% vs 2%, p=0.002), and delirium was also higher in patients who had block failure than success (18% vs 5%, p=0.06). Our block failure rate of 4.5% was lower than the range of 6%–60% in the literature 17–19…”
Section: Discussioncontrasting
confidence: 60%
“…While there were no differences in delirium by FICB status, it was interesting to find that patients who developed delirium were more likely to receive a second block than those who did not develop delirium (18% vs 2%, p=0.002), and delirium was also higher in patients who had block failure than success (18% vs 5%, p=0.06). Our block failure rate of 4.5% was lower than the range of 6%–60% in the literature 17–19…”
Section: Discussioncontrasting
confidence: 60%
“…Additionally, the duration of analgesia provided by a single-shot FIB is variable, ranging from 8 to 44 hours, and our median time from block placement to surgery was 19.2 hours. 41,42 Moreover, the majority of FIBs used in this study were single-shot blocks (59.8%). If the duration of analgesia provided by a single-shot block was a confounding factor, we would expect to see less difference in preoperative opioid consumption compared with our historical control.…”
Section: Discussionmentioning
confidence: 99%
“…This study had several limitations. First, we were unable to record the onset time of analgesia because the patients received the block whilst under the effect of spinal anesthesia, and we were also unable to determine the block duration because we did not observe the patients for more than 24 h. Levente et al [ 34 ] reported that the median duration of a conventional fascia iliaca block with 40 ml of 0.5% ropivacaine is 48 h and can be prolonged by increasing the volume and concentration of the local anesthetic. However, caution is advised to not exceed the limits for local anesthetic systemic toxicity when using high volumes and concentrations [ 35 ].…”
Section: Discussionmentioning