2008
DOI: 10.1007/s10973-007-8709-0
|View full text |Cite
|
Sign up to set email alerts
|

Effects of the type of calorimeter and the use of plasticizers and hydrophobizers on the measured hydration heat development of FGD gypsum

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(8 citation statements)
references
References 9 publications
0
8
0
Order By: Relevance
“…The heats of hydration for neat α-hemihydrate and βhemihydrate are reportedly 112 and 100 kJ•kg −1 , respectively. 11 The measured values listed in Table 4 were lower. The heat of hydration, for the Base1 composition, which comprised a combination of CaSO 4 •0.5H 2 O and Al, was measured as 83 ± 4 kJ•kg −1 .…”
Section: ■ Results and Discussionmentioning
confidence: 88%
See 1 more Smart Citation
“…The heats of hydration for neat α-hemihydrate and βhemihydrate are reportedly 112 and 100 kJ•kg −1 , respectively. 11 The measured values listed in Table 4 were lower. The heat of hydration, for the Base1 composition, which comprised a combination of CaSO 4 •0.5H 2 O and Al, was measured as 83 ± 4 kJ•kg −1 .…”
Section: ■ Results and Discussionmentioning
confidence: 88%
“…The kinetics of the calcium sulfate hydration reactions were investigated using isothermal heat flow calorimetry , at a temperature of 25 °C. The heat flow rate was measured as a function of time and the heat of hydration was determined with a TA Instruments TAM air flow calorimeter.…”
Section: Methodsmentioning
confidence: 99%
“…The isothermal heat flow calorimeter KC 01 [7] was applied for the measurement of hydration heat development in the analyzed alkali activated aluminosilicates. The device is based on the differential measurement of heat flow.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…The surface distribution of sorbed Pb was examined by Scanning Electron Microscope (SEM) Phenom XL (Phenom World, Eindhoven, the Netherland) with EDS (Energy-Dispersive X-ray spectroscopy) detector. The initial part of hydration process in cement pastes was monitored by isothermal calorimetry (homemade heat flow calorimeter KC01) [38]; two replicates were done. The compressive strength of pastes (after 3, 7, 14 and 28 days of curing) was determined by help of MTS Criterion 43 device with controlled speed of deformation (0.2 mm/s).…”
Section: Methodsmentioning
confidence: 99%