2018
DOI: 10.1016/j.ogla.2018.10.006
|View full text |Cite
|
Sign up to set email alerts
|

Effects of the Relative Positioning between the Disc-Fovea Angle and Localized Optic Disc Defects on the 10-2 Visual Field Results in Glaucoma

Abstract: Purpose: To investigate the effects of the foveal position relative to the optic disc on the 10-2 visual field (VF) results of glaucoma patients with localized inferotemporal neuroretinal rim defects (ITD). Design: Cross-sectional study. Participants: Fifty-seven eyes of 35 open-angle glaucoma (OAG) patients were included and divided into two groups based upon the presence (18 eyes) or not (39 eyes) of ITD. Methods: Three different parameters obtained from a spectral domain optic coherence tomography (sd… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 19 publications
(34 reference statements)
0
4
0
Order By: Relevance
“…We justify this difference by the small number of patients in the study, a different number of participants between the groups (20 eyes in the myopic Group vs. 32 eyes in the hyperopic Group), and all patients having negative DFA. Matos et al did not report an association of the central defect with DFA but with the vertical deviation of the fovea (10) . One of the main limitations of this study was the possibility of inclination and rotation of the optic nerve.…”
Section: Discussionmentioning
confidence: 95%
See 3 more Smart Citations
“…We justify this difference by the small number of patients in the study, a different number of participants between the groups (20 eyes in the myopic Group vs. 32 eyes in the hyperopic Group), and all patients having negative DFA. Matos et al did not report an association of the central defect with DFA but with the vertical deviation of the fovea (10) . One of the main limitations of this study was the possibility of inclination and rotation of the optic nerve.…”
Section: Discussionmentioning
confidence: 95%
“…We performed DFA measurements in a masked way and with good agreement between measurements, although the measurements were examiner-dependent. The sample size calculation was based on previous studies (10,14,15) , and the low number of participants can also be a limitation of the study.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations