2021
DOI: 10.1109/access.2020.3049089
|View full text |Cite
|
Sign up to set email alerts
|

Effects of Temperature Gradient on Electrical Tree Initiation and Breakdown Phenomenon in XLPE Under Harmonic Superimposed DC Voltage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
5
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 36 publications
1
5
0
Order By: Relevance
“…The breakdown strength was slightly larger for CV@GT-Cs rather than CV@GT-As in Figure 8 b. The difference between the heated cathode and anode cases has been reported in previous studies [ 44 , 45 ]. The difference between @GT-Cs and @GT-As originated from the position of the maximum electric field, as depicted in Figure 3 and Figure 4 .…”
Section: Prediction Of Breakdown Strength With Electro-mechanical Threshold Energy Conditionsupporting
confidence: 67%
See 1 more Smart Citation
“…The breakdown strength was slightly larger for CV@GT-Cs rather than CV@GT-As in Figure 8 b. The difference between the heated cathode and anode cases has been reported in previous studies [ 44 , 45 ]. The difference between @GT-Cs and @GT-As originated from the position of the maximum electric field, as depicted in Figure 3 and Figure 4 .…”
Section: Prediction Of Breakdown Strength With Electro-mechanical Threshold Energy Conditionsupporting
confidence: 67%
“…Numbers 1 to 3 indicate the cases at 30 °C~50 °C; 30 °C~70 °C; and 50 °C~70 °C, respectively. The breakdown strength decreased as the temperature gradient increased [ 44 ]. The breakdown strength was slightly larger for CV@GT-Cs rather than CV@GT-As in Figure 8 b.…”
Section: Prediction Of Breakdown Strength With Electro-mechanical Threshold Energy Conditionmentioning
confidence: 99%
“…In our previous work, we found that compared with 1st, 5th, 7th, 9th harmonic order, the electrical tree length and the inception probability reached the maximum values at 3rd harmonic voltage [18], implying that 3rd harmonic voltage has a great influence on the growth of electrical tree, so we select 150 Hz as the harmonic frequency in this paper. Specific electrical tree experimental platform diagrams, voltage waveform diagrams and other details of the electrical tree experimental setup can be referred to [14,16]. Two kinds of temperature gradients are set in the experiment: (1) The temperature on ground side is fixed at 20°C, and the temperature on high voltage side varies from 20 to 80°C;…”
Section: Experimental Apparatus and Proceduresmentioning
confidence: 99%
“…Each experimental group contains 20 test samples to ensure accuracy. More details could be referred to [14,16].…”
Section: Experimental Apparatus and Proceduresmentioning
confidence: 99%
See 1 more Smart Citation