2009
DOI: 10.1016/j.corsci.2008.12.005
|View full text |Cite
|
Sign up to set email alerts
|

Effects of scan rate on the potentiodynamic polarization curve obtained to determine the Tafel slopes and corrosion current density

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
127
0
1

Year Published

2013
2013
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 390 publications
(132 citation statements)
references
References 25 publications
4
127
0
1
Order By: Relevance
“…The corrosion current densities measured in the CMP chemical and tribocorrosion experiments may also support this opinion. The static current density under OCP, together with the current density calculated from Tafel plots, could indicate the corrosion behavior to some extent [21,24,48]. Figure 6 shows that without polishing, the corrosion current density in acid conditions is much higher than that under alkaline conditions, which corresponds well with the current density measured between sliding intervals at different pH values (Fig.…”
Section: Corrosion Behavior Of Copper In Periodate-based Solutionsupporting
confidence: 64%
“…The corrosion current densities measured in the CMP chemical and tribocorrosion experiments may also support this opinion. The static current density under OCP, together with the current density calculated from Tafel plots, could indicate the corrosion behavior to some extent [21,24,48]. Figure 6 shows that without polishing, the corrosion current density in acid conditions is much higher than that under alkaline conditions, which corresponds well with the current density measured between sliding intervals at different pH values (Fig.…”
Section: Corrosion Behavior Of Copper In Periodate-based Solutionsupporting
confidence: 64%
“…i corr values were determined by means of the Tafel extrapolation method by using the cathodic branches of the polarization curves. Firstly, it is seen that the cathodic branches of the polarization curves display a typical Tafel behavior instead of a limiting diffusion current, suggesting that the cathodic process is controlled by activation polarization instead of concentration polarization [19][20][21][22][23]. Secondly, the well-defined cathodic Tafel regions exist over one decade of current density which qualifies the other requirement for an accurate extrapolation.…”
Section: Potentiodynamic Polarizationmentioning
confidence: 90%
“…2(a-f) shows the potentiodynamic scans recorded for Hastelloy C-276 at 500 and 800°C, Hastelloy C-22 at 250 and 500°C and Stainless Steel 304 at 250 and 500°C in 13.4 NaCl: 33.7 KCl: 52.9 ZnCl 2 molten salt in the presence of air. In order to ensure a steady state polarization and to avoid disturbing the surface properties on the alloy electrode surfaces, a slower scan rate (0.1-0.3 mV s À1 ) and a narrow polarizing voltage window (±30 mV range from the OCV) were used, as suggested by Zhang et al [27]. The CR values estimated from the potentiodynamic scans are shown in Fig.…”
Section: Immersion Methodsmentioning
confidence: 99%