2011
DOI: 10.2528/pierm11092606
|View full text |Cite
|
Sign up to set email alerts
|

Effects of Reverse Radiation Noise on Millimeter-Wave Radiometric Imaging at Short Range

Abstract: Abstract-The existence of reverse radiation noise in the millimeterwave (MMW) radiometric imaging system with a superheterodyne receiver seriously affects the imaging experiments carried out at short range, thus leading to the degradation of MMW radiometric images and difficulty in recognizing targets. Based on the generation mechanism of reverse radiation noise, the specific influence on imaging for relative radiometry is investigated in this paper, and some methods of eliminating or reducing this noise are p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 11 publications
(10 reference statements)
0
6
0
Order By: Relevance
“…The LO is a critical element in the receiver development. Due to a finite mixer LO-RF isolation, the LO signal leakage from LO port to RF port of the mixer will result in reverse radiation and deteriorate the radiometer's performance greatly [17]. The employed LO with a Gunn diode shows a frequency of 94.5 GHz, with output power of 14 dBm and typical frequency stability of 5 MHz/ ∘ C. Besides, an isolator is placed between the coupler and the mixer to reduce the effects of reverse radiation, which performs a maximum insertion loss of 0.9 dB and a minimum isolation of 18 dB at operating frequencies.…”
Section: Receiver Descriptionmentioning
confidence: 99%
“…The LO is a critical element in the receiver development. Due to a finite mixer LO-RF isolation, the LO signal leakage from LO port to RF port of the mixer will result in reverse radiation and deteriorate the radiometer's performance greatly [17]. The employed LO with a Gunn diode shows a frequency of 94.5 GHz, with output power of 14 dBm and typical frequency stability of 5 MHz/ ∘ C. Besides, an isolator is placed between the coupler and the mixer to reduce the effects of reverse radiation, which performs a maximum insertion loss of 0.9 dB and a minimum isolation of 18 dB at operating frequencies.…”
Section: Receiver Descriptionmentioning
confidence: 99%
“…The schematic diagram of our MMW radiometer and a photograph of the experiment set-up [13] can be seen in Figure 5. The scene energy is collected by a W-band antenna and the frequency is down-converted by mixing with a 94.5GHz oscillator to the intermediate frequency (IF).…”
Section: Experiments Of Two-dimensional Detectionmentioning
confidence: 99%
“…For different objects, their capacities in emission, absorption and scattering of electromagnetic radiation within the MMW waveband are different; the characteristic information of the MMW radiation can be obtained through receiving the thermal radiation energy of objects by the high-sensitivity MMW radiometer [1,2]. The research on MMW radiation characteristics of the targets has played an important role in many fields, such as weapon system development, battlefield reconnaissance, range testing, stealth technology [3][4][5][6].…”
Section: Introductionmentioning
confidence: 99%