2016
DOI: 10.1253/circj.cj-16-0349
|View full text |Cite
|
Sign up to set email alerts
|

Effects of Proximal Pulmonary Artery Occlusion on Pulsatile Right Ventricular Afterload in Rats

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0
2

Year Published

2017
2017
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 35 publications
0
5
0
2
Order By: Relevance
“…The extension achieved by our approach is the ability to modulate all three Windkessel parameters in order to mimic diseased arterial systems presented to isolated tissues. These “diseased loads,” such as systemic hypertension (Segers et al, ) or pulmonary hypertension (Lankhaar et al, ; Fukumitsu et al, ), can be directly parameterized by measured values, or those obtained from the literature. The “diseased models” can be applied as real‐time loads for studying disease in healthy trabeculae.…”
Section: Discussionmentioning
confidence: 99%
“…The extension achieved by our approach is the ability to modulate all three Windkessel parameters in order to mimic diseased arterial systems presented to isolated tissues. These “diseased loads,” such as systemic hypertension (Segers et al, ) or pulmonary hypertension (Lankhaar et al, ; Fukumitsu et al, ), can be directly parameterized by measured values, or those obtained from the literature. The “diseased models” can be applied as real‐time loads for studying disease in healthy trabeculae.…”
Section: Discussionmentioning
confidence: 99%
“…Detailed surgical preparation has been described previously (Fukumitsu et al. ,b). Briefly, the rat was anesthetized with an intraperitoneal injection (2 mL/kg) of α‐chloralose (40 mg/mL) and urethane (250 mg/mL).…”
Section: Methodsmentioning
confidence: 99%
“…To achieve this goal, we used an in vivo experimental technique of estimating PAZ over a wide frequency range of physiological interest (0.1–50 Hz) in rats (Fukumitsu et al. ,b).…”
Section: Introductionmentioning
confidence: 99%
“…Это позволяет формировать значительные по объему исследуемые группы и таким образом частично компенсировать невысокую воспроизводимость этих моделей. В единичных работах использовались крысы [13] и кролики [14].…”
Section: моделирование тэла с помощью индукции тромбообразования In Vivounclassified
“…Однако у данной модели имеется ряд существенных недостатков: модель слабо отражает патофизиологию тромбоэмболического процесса и является необратимой. В связи с этим основной целью использования этой модели является изучение ремоделирования правого желудочка (ПЖ) после ТЭЛА [13].…”
Section: моделирование тэла с помощью индукции тромбообразования In Vivounclassified