2006
DOI: 10.1089/pho.2006.24.458
|View full text |Cite
|
Sign up to set email alerts
|

Effects of Power Densities, Continuous and Pulse Frequencies, and Number of Sessions of Low-Level Laser Therapy on Intact Rat Brain

Abstract: Long-term safety tests lasting 30 and 70 days at optimal 10x and 100x doses, as well as at multiple doses at the same power densities, indicate that the tested laser energy doses are safe under this treatment regime. Neurological deficits and histopathological damage to 750 mW/cm2 CW laser irradiation are attributed to thermal damage and not due to tissue-photon interactions.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
70
0

Year Published

2007
2007
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 120 publications
(72 citation statements)
references
References 13 publications
2
70
0
Order By: Relevance
“…In each case, any tissue damage appeared mechanical, caused by the optical fiber itself. When relating our results to those of Ilic and colleagues, 15 we may have needed to increase the power output at the optical fiber even more-perhaps by another factor of 10, which was well over the level needed for our positive neuroprotective result-to cause any neuronal damage and/or behavioral deficits.…”
Section: Toxicity Of Nir: Evidence Of Tissue Necrosis At the Implant mentioning
confidence: 68%
See 2 more Smart Citations
“…In each case, any tissue damage appeared mechanical, caused by the optical fiber itself. When relating our results to those of Ilic and colleagues, 15 we may have needed to increase the power output at the optical fiber even more-perhaps by another factor of 10, which was well over the level needed for our positive neuroprotective result-to cause any neuronal damage and/or behavioral deficits.…”
Section: Toxicity Of Nir: Evidence Of Tissue Necrosis At the Implant mentioning
confidence: 68%
“…Previous authors using external applications of NIr (for example, WARP-LED) at power intensities ranging from 7.5 to 75 mW/cm 2 have reported no adverse effect on brain tissue; 8,15,24,35,40 it is only at exceptionally high power intensities (750 mW/cm 2 ) that some neuronal damage and negative behavioral outcomes have been noted. 15 Notwithstanding this exceptionally high dose, the impact of NIr on all body tissues examined thus far has been overwhelmingly positive.…”
Section: Toxicity Of Nir: Evidence Of Tissue Necrosis At the Implant mentioning
confidence: 97%
See 1 more Smart Citation
“…Adverse behavioral effects can be induced with massive energy densities 100 times higher than those observed to induce beneficial effects, but even the adverse effects of high doses can be attenuated if the total energy is delivered using intermittent energy pulses. 85 …”
mentioning
confidence: 99%
“…These have been demonstrated by in vitro 3,4 and in vivo studies 5,6 . Researchers 1,7-11 studying the effect of various lasers on wound healing in diabetic animals have found a higher percentage of wound closure in diabetic and nondiabetic animals.…”
Section: Introductionmentioning
confidence: 85%